Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Model Number | 1587 FC | |
| Product Type | Insulation Tester | |
| Tester Type | Insulation Multimeter | |
| Minimum Test Voltage | 50V | |
| Maximum Test Voltage | 1000V | |
| Display Type | LCD Backlight | |
| Test Current | 1mA | |
| Battery Life | 1000h | |
| Power Source | Battery | |
| Battery Type | AA | |
| Minimum Operating Temperature | -20°C | |
| Insulation Testing Resistance | 2GΩ | |
| Maximum Operating Temperature | 55°C | |
| Safety Category Level | CAT IV, CAT III | |
| Safety Category Voltage | 600, 1000V | |
| Length | 203mm | |
| Height | 50mm | |
| Standards/Approvals | CE, CSA | |
| Width | 100mm | |
| Weight | 550g | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Model Number 1587 FC | ||
Product Type Insulation Tester | ||
Tester Type Insulation Multimeter | ||
Minimum Test Voltage 50V | ||
Maximum Test Voltage 1000V | ||
Display Type LCD Backlight | ||
Test Current 1mA | ||
Battery Life 1000h | ||
Power Source Battery | ||
Battery Type AA | ||
Minimum Operating Temperature -20°C | ||
Insulation Testing Resistance 2GΩ | ||
Maximum Operating Temperature 55°C | ||
Safety Category Level CAT IV, CAT III | ||
Safety Category Voltage 600, 1000V | ||
Length 203mm | ||
Height 50mm | ||
Standards/Approvals CE, CSA | ||
Width 100mm | ||
Weight 550g | ||
RoHS Status: Exempt
- COO (Country of Origin):
- US
Fluke Insulation Tester, 0.01MΩ to 2GΩ Insulation Testing Resistance, 1000V Maximum Test Voltage - FLUKE-1587 FC
This insulation tester is a handheld, battery-powered instrument that combines insulation measurement with multimeter functions for field diagnostics and maintenance in electrical, automation and mechanical settings. It performs insulation resistance testing up to very high values, applies selectable test voltages for diverse systems, and includes features for safe live-circuit detection and Rapid discharge of capacitive voltage for on-site use.
Features & Benefits
• 0.01MΩ to 2GΩ measurement range provides high-accuracy insulation readings
• Selectable 50V–1000V test voltages suit multiple installation voltages
• Live-circuit inhibit prevents testing when greater than 30V is present for safety
• 1mA test current delivers consistent, standardised insulation stress
• AA battery operation gives extended field use with 1000 h meter life
• LCD backlight display improves readability in dim environments
• Selectable 50V–1000V test voltages suit multiple installation voltages
• Live-circuit inhibit prevents testing when greater than 30V is present for safety
• 1mA test current delivers consistent, standardised insulation stress
• AA battery operation gives extended field use with 1000 h meter life
• LCD backlight display improves readability in dim environments
**Applications**
• Suitable for fault-finding on motor windings and drive systems using VFD measurements
• Ideal for insulation verification on switchgear and high-voltage cabling
• Used for preventive maintenance and asset trending in industrial plants
• Can be used for insulation checks on control panels and distribution boards
• Suitable for site surveys where portable CAT IV/CAT III measurement is required
• Ideal for insulation verification on switchgear and high-voltage cabling
• Used for preventive maintenance and asset trending in industrial plants
• Can be used for insulation checks on control panels and distribution boards
• Suitable for site surveys where portable CAT IV/CAT III measurement is required
How does the instrument protect against charged capacitors after testing?
It performs an automatic discharge with a typical release time under 0.5 s for capacitors of 1 μF or less.
What environmental conditions permit normal operation?
Operating temperature range is −20°C to 55°C with non‑condensing humidity limits up to 95% at 10°C–30°C, reducing at higher temperatures.
What measurement category and voltage ratings apply for on-site safety?
It is rated for both CAT IV 600V and CAT III 1000V measurement environments and accepts a maximum Terminal voltage of 1000 V.
What data and connectivity options are available for diagnostics?
The unit supports wireless data transfer, timed PI/DAR ratio logging, trend graphing and remote memory storage when used with the companion measurements app.
Supplied with
The Fluke 1587 FC Insulation Multimeter comes with a remote probe, test leads, alligator clips, K-type thermocouple, hard case and user documentation.
Related links
- Fluke 1587 Insulation Tester 1000 V Max CAT IV, CAT III
- Fluke 1507 Insulation Tester 1000 V Max CAT IV
- Fluke 1555 FC Insulation Tester 10000 V Max CAT III
- Fluke 1503 Insulation Tester 1000 V Max CAT III
- Fluke 1550C FC Kit Insulation Tester 5000 V Max CAT III
- Fluke 1550C FC Insulation Tester 5000 V Max CAT III, CAT IV
- RS PRO RS-9985 Insulation Tester 1000 V Max CAT IV, CAT III
- Fluke 1577 Insulation Tester 1000 V Max CAT IV