| Brand | Fluke | |
| Product Type | Clamp Meter | |
| Maximum DC Current Measurement | 999.9A | |
| Resistance Resolution | 10Ω | |
| Maximum AC Voltage Measurement | 1000V ac | |
| Maximum DC Voltage Measurement | 1000V dc | |
| Maximum Resistance Measurement | 60kΩ | |
| Model Number | 377 FC | |
| AC Current Accuracy | ±3 % rdg + 5 Digits | |
| DC Voltage Accuracy | 1 % ±10 digits | |
| Clamp Meter Type | AC/DC Clamp Meter | |
| DC Voltage Resolution | 0.1 V (≤600.0 V);1 V (≤1000 V) | |
| Maximum Jaw Opening | 34mm | |
| DC Current Accuracy | 2 % rdg ±5 Digits | |
| AC Voltage Resolution | 1V ac | |
| Minimum Operating Temperature | -10°C | |
| AC Voltage Accuracy | ±5 % rdg + 5 Digits | |
| Resistance Measurement Accuracy | ±1 % rdg + 5 Digits | |
| AC Current Resolution | 1A | |
| DC Current Resolution | 100mA | |
| Maximum Operating Temperature | 50°C | |
| Weight | 363g | |
| Length | 274mm | |
| Standards/Approvals | IEC 60529, IEC 613261, IEC 6132622, IEC 6155713, IEC 610101 | |
| Width | 86mm | |
| Height | 47mm | |
| True RMS | Yes | |
| Functions Measured | Frequency, AC Voltage, DC Current, DC Voltage, Resistance, Capacitance, AC Current | |
| Battery Type | AA | |
| Safety Category Level | CAT IV, CAT III | |
| Display Type | LCD | |
| Battery Life | 200h | |
| Non-Contact Voltage Detector | Yes | |
| Power Source | Battery | |
| Safety Category Voltage | 600V, 1V | |
| Maximum AC Current Measurement | 2.5kA | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Product Type Clamp Meter | ||
Maximum DC Current Measurement 999.9A | ||
Resistance Resolution 10Ω | ||
Maximum AC Voltage Measurement 1000V ac | ||
Maximum DC Voltage Measurement 1000V dc | ||
Maximum Resistance Measurement 60kΩ | ||
Model Number 377 FC | ||
AC Current Accuracy ±3 % rdg + 5 Digits | ||
DC Voltage Accuracy 1 % ±10 digits | ||
Clamp Meter Type AC/DC Clamp Meter | ||
DC Voltage Resolution 0.1 V (≤600.0 V);1 V (≤1000 V) | ||
Maximum Jaw Opening 34mm | ||
DC Current Accuracy 2 % rdg ±5 Digits | ||
AC Voltage Resolution 1V ac | ||
Minimum Operating Temperature -10°C | ||
AC Voltage Accuracy ±5 % rdg + 5 Digits | ||
Resistance Measurement Accuracy ±1 % rdg + 5 Digits | ||
AC Current Resolution 1A | ||
DC Current Resolution 100mA | ||
Maximum Operating Temperature 50°C | ||
Weight 363g | ||
Length 274mm | ||
Standards/Approvals IEC 60529, IEC 613261, IEC 6132622, IEC 6155713, IEC 610101 | ||
Width 86mm | ||
Height 47mm | ||
True RMS Yes | ||
Functions Measured Frequency, AC Voltage, DC Current, DC Voltage, Resistance, Capacitance, AC Current | ||
Battery Type AA | ||
Safety Category Level CAT IV, CAT III | ||
Display Type LCD | ||
Battery Life 200h | ||
Non-Contact Voltage Detector Yes | ||
Power Source Battery | ||
Safety Category Voltage 600V, 1V | ||
Maximum AC Current Measurement 2.5kA | ||
- COO (Country of Origin):
- US
Fluke Clamp Meter, 2500A Maximum AC Current Measurement, 1000V Maximum AC Voltage Measurement - FLUKE-377 FC/E
Features and Benefits:
• 2500A maximum AC current supports heavy-current diagnostics
• 1000V AC/DC rating permits testing up to high-voltage circuits
• 34mm jaw opening allows clamping around large conductors
• 200h battery life reduces interruptions during extended use
• Resistance, capacitance and frequency functions expand diagnostic scope
Applications
• Ideal for service engineers inspecting industrial motor supplies
• Used for verifying insulation and continuity in electrical panels
• Can be used for maintenance of renewable-energy inverter systems
• Used with live circuits where non-contact voltage detection is required
What accuracy can I expect for DC current measurements?
Which safety categories and standards does it comply with?
How does the display present measurement data?
What is the maximum resistance and its precision?
Supplied with
• iFlex flexible current probe (18 inches; 48 cm)
• TL224 silicone insulated test leads
• TP175 adjustable length test probes
• AC285 grounding clip
• TPAK magnetic hanging kit, with 9 inch (23 cm) hanging strap
• Carrying case
• Quick reference guide
Related links
- Fluke 374 FC Clamp Meter CAT IV Non-Contact Voltage Detector
- Fluke 375 FC Clamp Meter CAT IV Non-Contact Voltage Detector
- Fluke 376 FC Clamp Meter CAT IV Non-Contact Voltage Detector
- Fluke 378 FC Clamp Meter CAT IV 600 V Non-Contact Voltage
- Fluke 381 Clamp Meter CAT III Non-Contact Voltage Detector
- Fluke 355 Clamp Meter CAT III Non-Contact Voltage Detector
- RS PRO 157B Clamp Meter 1000 A ac 1000 V dc 999.9 V ac CAT IV, CAT III Non-Contact Voltage Detector
- Fluke 902 FC Clamp Meter, 200 μA 600 A 600 V dc 600 V ac CAT III Non-Contact Voltage Detector