Fluke 374 FC Clamp Meter, 600 A 2.5 kA 600 V dc 1000 V ac CAT III, CAT IV Non-Contact Voltage Detector
- RS Stock No.:
- 905-5911
- Distrelec Article No.:
- 300-37-361
- Mfr. Part No.:
- FLUKE-374 FC
- Manufacturer:
- Fluke
Alternative
This product is not currently available. Here is our alternative recommendation.
Each
SGD438.78
(exc. GST)
SGD478.27
(inc. GST)
- RS Stock No.:
- 905-5911
- Distrelec Article No.:
- 300-37-361
- Mfr. Part No.:
- FLUKE-374 FC
- Manufacturer:
- Fluke
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Product Type | Clamp Meter | |
| Maximum DC Current Measurement | 600A | |
| Resistance Resolution | 1Ω | |
| Maximum AC Voltage Measurement | 1000V ac | |
| Maximum DC Voltage Measurement | 600V dc | |
| Maximum Resistance Measurement | 6000Ω | |
| Model Number | 374 FC | |
| DC Current Accuracy | ±2 % rdg + 5 Digits | |
| DC Current Resolution | 100mA | |
| DC Voltage Resolution | 0.1 V | |
| AC Current Accuracy | 2% ±5 Digits (Jaw), 3% ±5 (Probe) | |
| Resistance Measurement Accuracy | ±1 % rdg + 5 Digits | |
| AC Current Resolution | 100mA | |
| Minimum Operating Temperature | -10°C | |
| AC Voltage Accuracy | 1 % ± 5 | |
| AC Voltage Resolution | 100mV | |
| Maximum Jaw Opening | 34mm | |
| DC Voltage Accuracy | ±1 % rdg + 5 Digits | |
| Clamp Meter Type | AC/DC Clamp Meter | |
| Maximum Operating Temperature | 50°C | |
| Standards/Approvals | IEC 61010-1IEC 61010-2-032IEC 61010-2-033IEC 60529: IP30FCC ID:T68-FBLEIC:6627A-FBLEIEC 61326-1IEC 61326-2-2CISPR 11 | |
| Weight | 388g | |
| Width | 83mm | |
| Length | 246mm | |
| Height | 43mm | |
| True RMS | Yes | |
| Functions Measured | Temperature, Resistance, DC Current, AC Voltage, AC Current, DC Voltage | |
| Safety Category Voltage | 1kV, 600kV | |
| Power Source | Battery | |
| Display Type | LCD Backlight | |
| Battery Type | AA IEC LR06 | |
| Safety Category Level | CAT III, CAT IV | |
| Non-Contact Voltage Detector | Yes | |
| Maximum AC Current Measurement | 2.5kA | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Product Type Clamp Meter | ||
Maximum DC Current Measurement 600A | ||
Resistance Resolution 1Ω | ||
Maximum AC Voltage Measurement 1000V ac | ||
Maximum DC Voltage Measurement 600V dc | ||
Maximum Resistance Measurement 6000Ω | ||
Model Number 374 FC | ||
DC Current Accuracy ±2 % rdg + 5 Digits | ||
DC Current Resolution 100mA | ||
DC Voltage Resolution 0.1 V | ||
AC Current Accuracy 2% ±5 Digits (Jaw), 3% ±5 (Probe) | ||
Resistance Measurement Accuracy ±1 % rdg + 5 Digits | ||
AC Current Resolution 100mA | ||
Minimum Operating Temperature -10°C | ||
AC Voltage Accuracy 1 % ± 5 | ||
AC Voltage Resolution 100mV | ||
Maximum Jaw Opening 34mm | ||
DC Voltage Accuracy ±1 % rdg + 5 Digits | ||
Clamp Meter Type AC/DC Clamp Meter | ||
Maximum Operating Temperature 50°C | ||
Standards/Approvals IEC 61010-1IEC 61010-2-032IEC 61010-2-033IEC 60529: IP30FCC ID:T68-FBLEIC:6627A-FBLEIEC 61326-1IEC 61326-2-2CISPR 11 | ||
Weight 388g | ||
Width 83mm | ||
Length 246mm | ||
Height 43mm | ||
True RMS Yes | ||
Functions Measured Temperature, Resistance, DC Current, AC Voltage, AC Current, DC Voltage | ||
Safety Category Voltage 1kV, 600kV | ||
Power Source Battery | ||
Display Type LCD Backlight | ||
Battery Type AA IEC LR06 | ||
Safety Category Level CAT III, CAT IV | ||
Non-Contact Voltage Detector Yes | ||
Maximum AC Current Measurement 2.5kA | ||
RoHS Status: Exempt
- COO (Country of Origin):
- MY
Fluke Clamp Meter, 34mm Maximum Jaw Opening, 2500A Maximum AC Current Measurement - FLUKE-374 FC
Features and Benefits:
• 2500A measurement with flexible probe for large conductors
• 1000V measurement with CAT IV600V/CAT III1000V safety rating
• 0.1A resolution for precise current monitoring
• Integrated VFD low-pass filter for motor-drive accuracy
• Backlit LCD with AA battery power for low-light operation
Applications
• Used for motor start inrush diagnostics on industrial drives
• Ideal for high-current distribution and busbar checks
• Can be used for field data collection and report sharing
• Used with flexible probe to access densely packed conductors
What battery type does it use and how are replacements sourced?
How does it Record measurements for later analysis?
What is the maximum jaw opening and why does it matter?
Which ranges are available for resistance and capacitance measurements?
What environmental conditions can it tolerate during operation?
Related links
- Fluke 375 FC Clamp Meter CAT IV Non-Contact Voltage Detector
- Fluke 376 FC Clamp Meter CAT IV Non-Contact Voltage Detector
- Fluke 377 FC Clamp Meter CAT III Non-Contact Voltage Detector
- Fluke 376 Clamp Meter CAT IV Non-Contact Voltage Detector
- FLIR VT8 Clamp Meter CAT IV Non-Contact Voltage Detector
- Megger DPM1000 Clamp Meter CAT IV Non-Contact Voltage Detector
- RS PRO 156B Clamp Meter CAT IV Non-Contact Voltage Detector
- Megger DCM1500S Clamp Meter CAT IV Non-Contact Voltage Detector