Fluke 902 FC Clamp Meter, 200 μA 600 A 600 V dc 600 V ac CAT III Non-Contact Voltage Detector
- RS Stock No.:
- 917-5368
- Distrelec Article No.:
- 300-47-593
- Mfr. Part No.:
- FLUKE-902 FC
- Manufacturer:
- Fluke
Alternative
This product is not currently available. Here is our alternative recommendation.
Each
SGD378.90
(exc. GST)
SGD413.00
(inc. GST)
- RS Stock No.:
- 917-5368
- Distrelec Article No.:
- 300-47-593
- Mfr. Part No.:
- FLUKE-902 FC
- Manufacturer:
- Fluke
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Product Type | Clamp Meter | |
| Resistance Resolution | 1Ω | |
| Maximum DC Current Measurement | 200μA | |
| Maximum AC Voltage Measurement | 600V ac | |
| Maximum DC Voltage Measurement | 600V dc | |
| Maximum Resistance Measurement | 6mΩ | |
| Model Number | 902 FC | |
| AC Voltage Resolution | 100mV ac | |
| AC Voltage Accuracy | 1.5 % ± 5 | |
| Minimum Operating Temperature | -10°C | |
| Temperature Measurement Accuracy | 1 % rgd ± 8 Digits % | |
| AC Current Accuracy | 2 % | |
| Temperature Resolution | 0.1°C | |
| DC Voltage Accuracy | ±1 % rdg + 5 Digits | |
| Clamp Meter Type | HVAC Clamp Meter | |
| AC Current Resolution | 100mA | |
| Resistance Measurement Accuracy | 1.5 % | |
| DC Voltage Resolution | 100 mV dc | |
| DC Current Resolution | 100nA | |
| DC Current Accuracy | ±1 % rdg + 4 Digits | |
| Maximum Operating Temperature | 50°C | |
| Length | 62mm | |
| Height | 273mm | |
| Weight | 700g | |
| Standards/Approvals | IEC 61010-1IEC 61010-2-032: CAT III 1000 V / CAT IV 600 VIEC 61010-2-033: CAT III 1000 V / CAT IV 600 VIEC 60529: IP30non-operatingFCC ID:T68-FBLEIC:6627A-FBLEIEC 61326-1IEC 61326-2-2CISPR 11: Group 1Class AKCC: Class A EquipmentFCC: 47 CFR 15 subpart B | |
| Width | 108mm | |
| True RMS | Yes | |
| Functions Measured | AC Current, DC Current, Capacitance, AC Voltage, Temperature, Resistance, Continuity, DC Voltage | |
| Battery Type | AA Alkaline | |
| Battery Life | 12h | |
| Safety Category Level | CAT III | |
| Maximum AC Current Measurement | 600A | |
| Maximum Temperature Measurement | 400°C | |
| Display Type | LCD | |
| Non-Contact Voltage Detector | Yes | |
| Safety Category Voltage | 600V | |
| Power Source | Battery | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Product Type Clamp Meter | ||
Resistance Resolution 1Ω | ||
Maximum DC Current Measurement 200μA | ||
Maximum AC Voltage Measurement 600V ac | ||
Maximum DC Voltage Measurement 600V dc | ||
Maximum Resistance Measurement 6mΩ | ||
Model Number 902 FC | ||
AC Voltage Resolution 100mV ac | ||
AC Voltage Accuracy 1.5 % ± 5 | ||
Minimum Operating Temperature -10°C | ||
Temperature Measurement Accuracy 1 % rgd ± 8 Digits % | ||
AC Current Accuracy 2 % | ||
Temperature Resolution 0.1°C | ||
DC Voltage Accuracy ±1 % rdg + 5 Digits | ||
Clamp Meter Type HVAC Clamp Meter | ||
AC Current Resolution 100mA | ||
Resistance Measurement Accuracy 1.5 % | ||
DC Voltage Resolution 100 mV dc | ||
DC Current Resolution 100nA | ||
DC Current Accuracy ±1 % rdg + 4 Digits | ||
Maximum Operating Temperature 50°C | ||
Length 62mm | ||
Height 273mm | ||
Weight 700g | ||
Standards/Approvals IEC 61010-1IEC 61010-2-032: CAT III 1000 V / CAT IV 600 VIEC 61010-2-033: CAT III 1000 V / CAT IV 600 VIEC 60529: IP30non-operatingFCC ID:T68-FBLEIC:6627A-FBLEIEC 61326-1IEC 61326-2-2CISPR 11: Group 1Class AKCC: Class A EquipmentFCC: 47 CFR 15 subpart B | ||
Width 108mm | ||
True RMS Yes | ||
Functions Measured AC Current, DC Current, Capacitance, AC Voltage, Temperature, Resistance, Continuity, DC Voltage | ||
Battery Type AA Alkaline | ||
Battery Life 12h | ||
Safety Category Level CAT III | ||
Maximum AC Current Measurement 600A | ||
Maximum Temperature Measurement 400°C | ||
Display Type LCD | ||
Non-Contact Voltage Detector Yes | ||
Safety Category Voltage 600V | ||
Power Source Battery | ||
RoHS Status: Exempt
Fluke Clamp Meter, 600V Maximum AC Voltage, 600A Maximum AC Current - FLUKE-902 FC
Features and Benefits:
• 600V AC and DC range enables broad circuit testing
• True RMS sensing for accurate non-linear signal measurement
• Temperature measurement to 400°C for thermocouple checks
• 200μA DC sensitivity for flame sensor current verification
• 1000μF capacitance range for motor-start capacitor checks
Applications
• Ideal for measuring flame sensor and pilot currents
• Used with contact thermocouples for temperature verification
• Can be used for capacitor health checks during maintenance
• Suitable for voltage-presence checks without contact detection
What battery type does it use and how long will it run?
What safety ratings apply for use on site?
How does it Record and share measurements remotely?
What environmental limits affect operation and storage?
How is continuity and low-resistance measurement signalled?
Related links
- Fluke 375 FC Clamp Meter CAT IV Non-Contact Voltage Detector
- Fluke 374 FC Clamp Meter CAT IV Non-Contact Voltage Detector
- Fluke A3000 FC Clamp Meter, 400 mA 400 A 600 V dc 600 V ac CAT III Non-Contact Voltage Detector
- Fluke 376 FC Clamp Meter CAT IV Non-Contact Voltage Detector
- Fluke 377 FC Clamp Meter CAT III Non-Contact Voltage Detector
- Fluke 369 FC Clamp Meter 60 A CAT III Non-Contact Voltage Detector
- Fluke A3002 FC Clamp Meter CAT III Non-Contact Voltage Detector
- Fluke 323 Clamp Meter 400 A 600 V dc 600 V ac CAT IV, CAT III Non-Contact Voltage Detector