Schneider Electric iDPN Series Residual Current Device, 32A, 1-Pole, 300 mA, Type B, 6 kA
- RS Stock No.:
- 790-9487
- Mfr. Part No.:
- A9D69632
- Manufacturer:
- Schneider Electric
Currently unavailable
We don't know if this item will be back in stock, RS intend to remove it from our range soon.
- RS Stock No.:
- 790-9487
- Mfr. Part No.:
- A9D69632
- Manufacturer:
- Schneider Electric
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Schneider Electric | |
| Product Type | Residual Current Device | |
| Current Rating | 32A | |
| Number of Poles | 1 | |
| Series | iDPN | |
| Range | Acti9 | |
| Trip Sensitivity | 300mA | |
| Mount Type | DIN Rail | |
| Tripping Characteristics | Type B | |
| Terminal Type | Screw | |
| Standards/Approvals | RoHS, REACH, EN/IEC 61009-2-1 | |
| Width | 36mm | |
| Height | 85mm | |
| Depth | 73mm | |
| Breaking Capacity | 6kA | |
| Earth Leakage Protection Type | Type A | |
| Break Time | Instantaneous | |
| Rated AC Voltage | 230V ac | |
| Tripping Mechanism | Thermal Magnetic | |
| Application | Distribution | |
| Reset Actuator Type | Toggle Switch | |
| Select all | ||
|---|---|---|
Brand Schneider Electric | ||
Product Type Residual Current Device | ||
Current Rating 32A | ||
Number of Poles 1 | ||
Series iDPN | ||
Range Acti9 | ||
Trip Sensitivity 300mA | ||
Mount Type DIN Rail | ||
Tripping Characteristics Type B | ||
Terminal Type Screw | ||
Standards/Approvals RoHS, REACH, EN/IEC 61009-2-1 | ||
Width 36mm | ||
Height 85mm | ||
Depth 73mm | ||
Breaking Capacity 6kA | ||
Earth Leakage Protection Type Type A | ||
Break Time Instantaneous | ||
Rated AC Voltage 230V ac | ||
Tripping Mechanism Thermal Magnetic | ||
Application Distribution | ||
Reset Actuator Type Toggle Switch | ||
Schneider Electric RCD, 4kV Rated Impulse Withstand Voltage, IP20 Rating - Acti 9 Series - A9D69632
For a reliable and comprehensive response to electrical faults, break out this RCD from Schneider Electric. Combining the functions of an MCB and an RCBO, it's your all-in-one safety solution in commercial or industrial settings. Type-B tripping characteristics ensure it cuts power to your circuit and disconnects downstream devices whenever currents exceed three to five times the rated value of 32A. Its thermal-magnetic breaking mechanism means it de-energises consistently when exposed to overload voltages or excessive temperatures, so you can trust it's hot on preventing the risk of fire. Integrated earth-leakage protection chases residual currents straight to ground, preventing shocks.
• Simplifies wiring needs by 50% for measurably easier setup
• Provides continuous short-circuit protection so your kit is safe to handle
• Clips on to a standard DIN rail for easy installation without tools
Applications
• Railway industry
• Utility companies
• Healthcare sector
Does this RCD protect against electrical surges?
Yes. This unit's impulse withstand rating of 4kV protects you and your equipment even in case of significant voltage surges.
Related links
- Schneider Electric iDPN Series Residual Current Device 1-Pole Type C, 6000 A 230V ac
- Schneider Electric iDPN Series Residual Current Circuit Breaker 1-Pole Type C, 6000 A 400V
- Schneider Electric iDPN Series Residual Current Device 1-Pole Type C, 6000 A 230V ac
- Legrand DX3 Series Residual Current Device 1-Pole Type C 230V ac
- Legrand DX3 Series Residual Current Device 3+N-Pole Type AC 400V ac
- Legrand DX3 Series Residual Current Device 1-Pole Type C 230V ac
- Legrand DX3 Series Residual Current Device 1-Pole Type C, 10 kA 230V ac
- Legrand DX3 Series Residual Current Device 1-Pole Type AC, 10 kA 230V ac