ABB F404 Series Residual Current Circuit Breaker, 63 A, 3-Pole, 30 mA, Type A, 1 kA 400 V ac
- RS Stock No.:
- 176-879
- Mfr. Part No.:
- 2CCF544310E0630 - F404A-K63/0.03,2CC
- Manufacturer:
- ABB
This image is representative of the product range
Subtotal (1 unit)*
SGD662.80
(exc. GST)
SGD722.45
(inc. GST)
FREE delivery for orders over $150, or create a business account to enjoy free delivery from just $28
Temporarily out of stock
- Shipping from 06 April 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | SGD662.80 |
*price indicative
- RS Stock No.:
- 176-879
- Mfr. Part No.:
- 2CCF544310E0630 - F404A-K63/0.03,2CC
- Manufacturer:
- ABB
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | ABB | |
| Product Type | Residual Current Circuit Breaker | |
| Current Rating | 63 A | |
| Number of Poles | 3 | |
| Range | SmiSSline | |
| Series | F404 | |
| Trip Sensitivity | 30mA | |
| Mount Type | Conductor Bar Mount | |
| Tripping Characteristics | Type A | |
| Terminal Type | Screw | |
| Standards/Approvals | UL 1053, IEC/EN 61008, REACH, RoHS | |
| Height | 91mm | |
| Depth | 75mm | |
| Width | 36 mm | |
| Breaking Capacity | 1kA | |
| Rated AC Voltage | 400 V ac | |
| Application | Residential | |
| Reset Actuator Type | Toggle Switch | |
| Break Time | Instantaneous | |
| Earth Leakage Protection Type | Type A | |
| Select all | ||
|---|---|---|
Brand ABB | ||
Product Type Residual Current Circuit Breaker | ||
Current Rating 63 A | ||
Number of Poles 3 | ||
Range SmiSSline | ||
Series F404 | ||
Trip Sensitivity 30mA | ||
Mount Type Conductor Bar Mount | ||
Tripping Characteristics Type A | ||
Terminal Type Screw | ||
Standards/Approvals UL 1053, IEC/EN 61008, REACH, RoHS | ||
Height 91mm | ||
Depth 75mm | ||
Width 36 mm | ||
Breaking Capacity 1kA | ||
Rated AC Voltage 400 V ac | ||
Application Residential | ||
Reset Actuator Type Toggle Switch | ||
Break Time Instantaneous | ||
Earth Leakage Protection Type Type A | ||
- COO (Country of Origin):
- CH
RCCB, F404-K, short time delayed
Time-delayed SMISSLINE RCCB
With integrated input wiring
Contact position display
Upper input terminals can be used as feed
Pluggable in any position
Sensitive to AC and pulsed DC fault currents
Double-level output terminal
Related links
- ABB F404 Series Residual Current Circuit Breaker 3-Pole Type A, 1 kA 400 V ac
- ABB F404 Series Residual Current Circuit Breaker 4-Pole Type A, 1 kA 400 V ac
- ABB F404 Series Residual Current Circuit Breaker 4-Pole Type A, 1 kA 400 V ac
- ABB F404 Series Residual Current Circuit Breaker 3-Pole Type A, 1 kA 400 V ac
- ABB F404 Series Residual Current Circuit Breaker 3-Pole Type A, 1 kA 400 V ac
- ABB F404 Series Residual Current Circuit Breaker 4-Pole Type A, 1 kA 400 V ac
- ABB F404 Series Residual Current Circuit Breaker 4-Pole Type A, 1 kA 400 V ac
- ABB F404 S Series Residual Current Circuit Breaker 4-Pole Type A, 63 A 400 V ac