Better World
Schneider Electric Acti 9 iC60H MCB, 1P, 25A Curve C, 100 → 133V AC, 72V DC, 10 kA Breaking Capacity
- RS Stock No.:
- 791-3300
- Mfr. Part No.:
- A9F54125
- Manufacturer:
- Schneider Electric
Subtotal (1 unit)*
SGD52.01
(exc. GST)
SGD56.69
(inc. GST)
FREE delivery for orders over $150, or create a business account to enjoy free delivery from just $28
Temporarily out of stock
- 40 unit(s) shipping from 16 January 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | SGD52.01 |
*price indicative
Better World
Our Better World range features products that make it easy for you to make a greener product choice you can trust. Click here to find out more.
- RS Stock No.:
- 791-3300
- Mfr. Part No.:
- A9F54125
- Manufacturer:
- Schneider Electric
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Schneider Electric | |
| Number of Poles | 1 | |
| Current Rating | 25A | |
| Tripping Characteristics | Type C | |
| Rated AC Voltage | 100 → 133 V, 12 → 60 V, 220 → 240V | |
| Rated DC Voltage | 72 V, 12 → 48V | |
| Breaking Capacity at Maximum Voltage Rating | 10 kA | |
| Range | Acti 9 | |
| Series | iC60H | |
| Circuit Breaker Type | MCB | |
| Width | 18mm | |
| Length | 85mm | |
| Mounting Style | DIN Rail Mount | |
| Depth | 78.5mm | |
| Model Number | A9F | |
| Better World Product | Yes | |
| Better World Verification | Green Premium | |
| Tripping Mechanism | Thermal-Magnetic | |
| Terminal Contact Type | Screw | |
| Reset Actuator Type | Rocker Switch | |
| Select all | ||
|---|---|---|
Brand Schneider Electric | ||
Number of Poles 1 | ||
Current Rating 25A | ||
Tripping Characteristics Type C | ||
Rated AC Voltage 100 → 133 V, 12 → 60 V, 220 → 240V | ||
Rated DC Voltage 72 V, 12 → 48V | ||
Breaking Capacity at Maximum Voltage Rating 10 kA | ||
Range Acti 9 | ||
Series iC60H | ||
Circuit Breaker Type MCB | ||
Width 18mm | ||
Length 85mm | ||
Mounting Style DIN Rail Mount | ||
Depth 78.5mm | ||
Model Number A9F | ||
Better World Product Yes | ||
Better World Verification Green Premium | ||
Tripping Mechanism Thermal-Magnetic | ||
Terminal Contact Type Screw | ||
Reset Actuator Type Rocker Switch | ||
- COO (Country of Origin):
- BG
Schneider Electric Acti9 iC60H MCBs 1 Pole
C60H series multi-standard circuit breakers combine circuit protection against short circuit currents and circuit protection against overload currents it also protects people against indirect contact with TN and IT neutral systems. Fully compliant with standards IEC/EN 60898 and IEC/EN 60947-2. ACTi 9 is fully tested, approved and certified by national and international third parties. It guarantees that your installation is safe and compliant with all relevant safety standards which demonstrates to your customers that you use industry-approved materials and best practices. These MCBs are normally used for high inductive loads where switching surges are high. Providing essential protection in industrial and commercial buildings, these miniature circuit breakers work especially well in polluted environments and networks.
Features and benefits:
VisiSafe guarantees the downstream circuit is always safe regardless of overvoltage conditions, even in the most demanding environments; the green strip indicates the safe position of contacts.
VisiTrip red window on the front face indicates fault tripping allowing fast diagnosis, resolution, and reclosing loads for easier building management and reduced downtime
VisiTrip red window on the front face indicates fault tripping allowing fast diagnosis, resolution, and reclosing loads for easier building management and reduced downtime
Benefits and Features
Downstream circuit is always safe
Class-2 insulation: ensures continuous protection for both operators and unqualified persons
Insulated terminals (IP20)
Highly durable with robust connections that provide twice the standard tightening torque
Provide greater continuity of service thanks to VisiTrip
Double clip for dismounting with comb busbar in place
Class-2 insulation: ensures continuous protection for both operators and unqualified persons
Insulated terminals (IP20)
Highly durable with robust connections that provide twice the standard tightening torque
Provide greater continuity of service thanks to VisiTrip
Double clip for dismounting with comb busbar in place
Standards
IEC 60898 - Relates to Low Voltage Circuit Breakers for use in household and similar
Installations. In the UK traditionally known as miniature circuit breakers
(MCBs).
IEC 60947-2 Relates to Low Voltage Circuit Breakers for use in industrial and similar
Installations. In the UK traditionally known as moulded case circuit breakers
(MCCBs) and also air circuit breakers (ACBs).
Installations. In the UK traditionally known as miniature circuit breakers
(MCBs).
IEC 60947-2 Relates to Low Voltage Circuit Breakers for use in industrial and similar
Installations. In the UK traditionally known as moulded case circuit breakers
(MCCBs) and also air circuit breakers (ACBs).
Q: What is the differences in the Tripping Curves B, C, and D?
A: Curve B: Tripping: 3 to 5 times the rated current.
Applications: protection of generators, persons, very long cables
Curve C: Tripping: 5 to 10 times the rated current
Applications: protection of circuits and general applications
Curve D: Tripping: 10 to 14 times the rated current
Applications: protection of high surge circuits, welders, transformers and motors
Applications: protection of generators, persons, very long cables
Curve C: Tripping: 5 to 10 times the rated current
Applications: protection of circuits and general applications
Curve D: Tripping: 10 to 14 times the rated current
Applications: protection of high surge circuits, welders, transformers and motors
Schneider Electric MCB, Thermal-Magnetic Tripping Mechanism, Screw Terminals - Acti9 iC60H Series - A9F54125
Insert this MCB from Schneider Electric in your circuit to shield personnel and equipment from overcurrents. Type C tripping characteristics mean it trips at five to 10 times its rated current of 25A. This makes it ideal for protecting a wide range of appliances, from lighting circuits to single-phase motors. The toggle features a VisiSafe green strip that lets you open the contact for safe downstream maintenance. Clip this breaker onto a DIN rail to make mounting a breeze.
Features & Benefits
• Securable with a padlock to protect against unauthorised use
• Trip indicator lets you see at a glance whether the circuit is energised
• Rated voltage of 240V AC means it's compatible with the UK mains supply
• Trip indicator lets you see at a glance whether the circuit is energised
• Rated voltage of 240V AC means it's compatible with the UK mains supply
Applications
• HVAC systems
• Commercial buildings
• Domestic lighting
• Commercial buildings
• Domestic lighting
What's the difference between a short circuit and an overload?
A short circuit is an unintended direct connection between conductors that causes a sudden flow of current, often due to damaged wiring. An overload results from excessive current drawn over time, usually because there are too many devices on a single circuit. This poses a fire hazard as it overheats circuits. Thanks to its thermal-magnetic tripping mechanism, this MCB protects against both short circuits and overloads.
Standards
EN/IEC 60947-2, EN/IEC 60898-1.
Merlin Gerin – MCBs
Miniature Circuit Breakers; Contact Position indicated by switch levers
Related links
- Schneider Electric Acti 9 iC60H MCB 25A Curve D 72V DC, 10 kA Breaking Capacity
- Schneider Electric Acti 9 iC60H MCB 25A Curve B 72V DC, 10 kA Breaking Capacity
- Schneider Electric Acti 9 iC60H MCB 10A Curve C 72V DC, 10 kA Breaking Capacity
- Schneider Electric Acti 9 iC60H MCB 50A Curve C 72V DC, 10 kA Breaking Capacity
- Schneider Electric Acti 9 iC60H MCB 63A Curve C 72V DC, 10 kA Breaking Capacity
- Schneider Electric Acti 9 iC60H MCB 32A Curve C 72V DC, 10 kA Breaking Capacity
- Schneider Electric Acti 9 iC60H MCB 6A Curve C 72V DC, 10 kA Breaking Capacity
- Schneider Electric Acti 9 iC60H MCB 40A Curve C 72V DC, 10 kA Breaking Capacity