ABB GJL131 Contactor, 24V ac Coil, 3-Pole, 20 A, 5.5 kW 24V ac, 4 NO, 690V
- RS Stock No.:
- 253-4824
- Mfr. Part No.:
- GJL1311911R0101
- Manufacturer:
- ABB
Subtotal (1 pack of 10 units)*
SGD1,667.26
(exc. GST)
SGD1,817.31
(inc. GST)
FREE delivery for orders over $150, or create a business account to enjoy free delivery from just $28
Stocked by manufacturer
- Ready to ship from 04 June 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit | Per Pack* |
|---|---|---|
| 10 + | SGD166.726 | SGD1,667.26 |
*price indicative
- RS Stock No.:
- 253-4824
- Mfr. Part No.:
- GJL1311911R0101
- Manufacturer:
- ABB
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | ABB | |
| Coil Voltage | 24V ac | |
| Product Type | Contactor | |
| Number of Poles | 3 | |
| Contact Voltage | 690V | |
| Contact Current | 20A | |
| Series | GJL131 | |
| Power Rating | 5.5kW | |
| Function | Reversing Contactor | |
| Mount Type | DIN Rail | |
| Normal State Configuration | 4 NO | |
| Number of Auxiliary Contacts | 1 | |
| Terminal Type | Screw | |
| Minimum Operating Temperature | -20°C | |
| Contactor Application | Control Unit | |
| Control Circuit Voltage Uc | 24V ac | |
| Operational Current Ie | 20A | |
| Maximum Operating Temperature | 55°C | |
| Width | 58mm | |
| Depth | 46.7mm | |
| Standards/Approvals | IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1 | |
| Length | 46.7mm | |
| Pole and Throw Configuration | 3 | |
| Select all | ||
|---|---|---|
Brand ABB | ||
Coil Voltage 24V ac | ||
Product Type Contactor | ||
Number of Poles 3 | ||
Contact Voltage 690V | ||
Contact Current 20A | ||
Series GJL131 | ||
Power Rating 5.5kW | ||
Function Reversing Contactor | ||
Mount Type DIN Rail | ||
Normal State Configuration 4 NO | ||
Number of Auxiliary Contacts 1 | ||
Terminal Type Screw | ||
Minimum Operating Temperature -20°C | ||
Contactor Application Control Unit | ||
Control Circuit Voltage Uc 24V ac | ||
Operational Current Ie 20A | ||
Maximum Operating Temperature 55°C | ||
Width 58mm | ||
Depth 46.7mm | ||
Standards/Approvals IEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1 | ||
Length 46.7mm | ||
Pole and Throw Configuration 3 | ||
- COO (Country of Origin):
- DE
ABB GJL131 Series Contactor, 20A Operational Current, 24V AC Control Circuit Voltage - GJL1311911R0101
This contactor is a reversing switching device designed for commercial electrical control, enabling motor direction change and power switching in three-phase systems. It operates on a low-voltage control supply and is intended for installation in industrial automation and electrical distribution panels where compact, DIN-rail or wall-mounted switching is required.
Features and Benefits:
• 24V AC Coil reduces control-circuit power requirements
• Three poles provide three-phase switching for motor circuits
• 20A operational current supports moderate load applications
• 5.5kW power rating permits control of small to medium motors
• Screw terminals ensure secure conductor connections
• Complies with IEC/EN and UL standards for recognised interoperability
• Three poles provide three-phase switching for motor circuits
• 20A operational current supports moderate load applications
• 5.5kW power rating permits control of small to medium motors
• Screw terminals ensure secure conductor connections
• Complies with IEC/EN and UL standards for recognised interoperability
Applications
• Suitable for reversing three-phase motor controllers in factories
• Ideal for control panels in commercial HVAC systems
• Used with automated machinery requiring direction change
• Can be used for switching loads up to 690V in distribution systems
• Ideal for control panels in commercial HVAC systems
• Used with automated machinery requiring direction change
• Can be used for switching loads up to 690V in distribution systems
What mounting options are available for installation flexibility?
It supports both DIN-rail mounting and direct wall attachment to suit different panel layouts.
How many auxiliary contacts are provided and what is their configuration?
There is one auxiliary contact fitted with a normally open arrangement for signalling or interlock use.
What environmental operating range should be considered for site selection?
The unit is specified to function between -20°C and 55°C ambient temperatures for typical indoor installations.
How many main poles are switched and what is the pole arrangement?
Three main poles are switched in a 3P configuration to manage three-phase supplies.
Which Terminal style is used for electrical connections?
Termination is by screw-type terminals for reliable clamping of conductors.
Related links
- ABB GJL131 Contactor 3-Pole 5.5 kW 24V ac 690V
- ABB GJL131 Contactor 4-Pole 5.5 kW 690V
- ABB GJL131 Contactor 3-Pole 5.5 kW 24V 690V
- ABB GJL131 Contactor 3-Pole 5.5 kW 24V ac 690V
- ABB GJL131 Contactor 3-Pole 5.5 kW 24V ac 250 V dc, 690V ac
- ABB GJL131 Contactor 3-Pole 5.5 kW 24V ac 600V
- ABB GJL131 Contactor 4-Pole 5.5 kW 24V ac 690V
- ABB GJL131 Contactor 4-Pole 5.5 kW 24V 690V dc