ABB GJL131 Contactor, 110V, 127 V, 110 V, 127 V Coil, 3-Pole, 12 A, 5.5 kW 127V, 3 NO/1 NC, 690V
- RS Stock No.:
- 721-284
- Mfr. Part No.:
- GJL1311009R8014
- Manufacturer:
- ABB
N
This image is representative of the product range
Subtotal (1 unit)*
SGD82.37
(exc. GST)
SGD89.78
(inc. GST)
FREE delivery for orders over $150, or create a business account to enjoy free delivery from just $28
Stocked by manufacturer
- Ready to ship from 15 May 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | SGD82.37 |
*price indicative
- RS Stock No.:
- 721-284
- Mfr. Part No.:
- GJL1311009R8014
- Manufacturer:
- ABB
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | ABB | |
| Product Type | Contactor | |
| Coil Voltage | 110, 127, 110, 127V | |
| Number of Poles | 3 | |
| Contact Voltage | 690V | |
| Contact Current | 12A | |
| Series | GJL131 | |
| Power Rating | 5.5kW | |
| Mount Type | DIN Rail | |
| Function | Mini Contactor | |
| Normal State Configuration | 3 NO/1 NC | |
| Auxiliary Contact Configuration | 0 NO/1 NC | |
| Number of Auxiliary Contacts | 1 | |
| Terminal Type | Solder Pin | |
| Operational Current Ie | 12A | |
| Control Circuit Voltage Uc | 127V | |
| Minimum Operating Temperature | -25°C | |
| Contactor Application | Control Unit | |
| Maximum Operating Temperature | 55°C | |
| Standards/Approvals | UL 60947-4-1, UL 60947-1, IEC/EN 60947-5-1, IEC/EN 60947-4-1, IEC/EN 60947-1 | |
| Length | 47.7mm | |
| Width | 48mm | |
| Depth | 47.7mm | |
| Pole and Throw Configuration | 3 | |
| Select all | ||
|---|---|---|
Brand ABB | ||
Product Type Contactor | ||
Coil Voltage 110, 127, 110, 127V | ||
Number of Poles 3 | ||
Contact Voltage 690V | ||
Contact Current 12A | ||
Series GJL131 | ||
Power Rating 5.5kW | ||
Mount Type DIN Rail | ||
Function Mini Contactor | ||
Normal State Configuration 3 NO/1 NC | ||
Auxiliary Contact Configuration 0 NO/1 NC | ||
Number of Auxiliary Contacts 1 | ||
Terminal Type Solder Pin | ||
Operational Current Ie 12A | ||
Control Circuit Voltage Uc 127V | ||
Minimum Operating Temperature -25°C | ||
Contactor Application Control Unit | ||
Maximum Operating Temperature 55°C | ||
Standards/Approvals UL 60947-4-1, UL 60947-1, IEC/EN 60947-5-1, IEC/EN 60947-4-1, IEC/EN 60947-1 | ||
Length 47.7mm | ||
Width 48mm | ||
Depth 47.7mm | ||
Pole and Throw Configuration 3 | ||
- COO (Country of Origin):
- DE
ABB GJL131 Series Contactor, 5.5kW Power Rating, 12A Operational Current - GJL1311009R8014
This contractor is a Compact switching device designed for commercial electrical control and motor management, providing three-phase switching in automation and electrical systems. It is intended for DIN-rail installation and operates reliably within typical commercial environments, offering a straightforward solution for controlling motors and power circuits where a small footprint and defined operational limits are required.
Features and Benefits:
• 3P configuration delivers three-pole switching for balanced loads
• Operational current 12A enables moderate motor and circuit control
• Contact voltage 690V supports higher-voltage distribution systems
• Power rating 5.5kW allows direct control of small motors
• Coil selectable at 110V or 127V suits varied control supplies
• One auxiliary contact provides additional control feedback
• Operational current 12A enables moderate motor and circuit control
• Contact voltage 690V supports higher-voltage distribution systems
• Power rating 5.5kW allows direct control of small motors
• Coil selectable at 110V or 127V suits varied control supplies
• One auxiliary contact provides additional control feedback
Applications
• Suitable for motor control in light industrial machinery
• Ideal for control panels in commercial building services
• Used with automation relays for sequence control tasks
• Can be used for switching resistive and small inductive loads
• Ideal for control panels in commercial building services
• Used with automation relays for sequence control tasks
• Can be used for switching resistive and small inductive loads
What mounting method does it use for panel installation?
It clips onto a DIN rail, enabling quick fitting and removal in standard control enclosures.
How is the auxiliary contact configured for control circuits?
There is one auxiliary contact arranged as 0NO/1NC to offer a normally closed feedback path.
What temperature range can it operate within safely?
The device is rated to function between -25°C and 55°C for typical commercial ambient conditions.
How are external connections MADE to the contact points?
Terminals are provided as solder-pin type for PCB or wired-assembly integration.
Related links
- ABB GJL131 Contactor 127 V 127 V Coil 12 A 3 NO/1 NC, 690V
- ABB GJL131 Contactor 127 V Coil 12 A 4 NO, 690V
- ABB GJL131 Contactor 127 V ac 127 V ac Coil 20 A 127 V ac 127
- ABB GJL131 Contactor 127 V ac Coil 5.5 kW 110V ac 4 NO, 690V
- ABB GJL131 Contactor 125 V 125 V Coil 20 A 4 NO, 690V
- ABB GJL131 Contactor 127 V ac Coil 20 A 127 V ac 690V
- ABB GJL131 Contactor 127 V ac Coil 20 A 127 V ac 690V
- Siemens Contactor 127 V Coil 225 A 2 NO/2 NC, 1kV