Fluke 365 Clamp Meter, 200 A 200 A 600 V dc 600 V ac CAT III Non-Contact Voltage Detector
- RS Stock No.:
- 705-1941
- Distrelec Article No.:
- 176-43-489
- Mfr. Part No.:
- Fluke 365
- Manufacturer:
- Fluke
Subtotal (1 unit)*
SGD604.00
(exc. GST)
SGD658.36
(inc. GST)
Units | Per unit |
|---|---|
| 1 + | SGD604.00 |
*price indicative
- RS Stock No.:
- 705-1941
- Distrelec Article No.:
- 176-43-489
- Mfr. Part No.:
- Fluke 365
- Manufacturer:
- Fluke
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Product Type | Clamp Meter | |
| Maximum DC Current Measurement | 200A | |
| Resistance Resolution | 100mΩ | |
| Maximum AC Voltage Measurement | 600V ac | |
| Maximum DC Voltage Measurement | 600V dc | |
| Maximum Resistance Measurement | 6kΩ | |
| Model Number | 365 | |
| Maximum Jaw Opening | 18mm | |
| AC Voltage Resolution | 100mV ac | |
| DC Voltage Resolution | 100 mV dc | |
| Minimum Operating Temperature | -10°C | |
| AC Voltage Accuracy | ±1.5 % rdg + 5 Digits | |
| AC Current Resolution | 100mA | |
| Resistance Measurement Accuracy | ± 1 % ± 5 Digits | |
| Clamp Meter Type | AC/DC Clamp Meter | |
| DC Voltage Accuracy | ±1 % rdg + 5 Digits | |
| DC Current Resolution | 100mA | |
| DC Current Accuracy | ±2 % rdg + 5 Digits | |
| AC Current Accuracy | ±2 % rdg + 5 Digits | |
| Maximum Operating Temperature | 50°C | |
| Length | 225mm | |
| Weight | 275g | |
| Width | 65mm | |
| Standards/Approvals | CAN/CSA-C22.2 No. 61010-1-04, UL 61010-1:2004 | |
| Height | 46mm | |
| True RMS | Yes | |
| Functions Measured | Resistance, Continuity, DC Voltage, AC Current, AC Voltage, DC Current | |
| Maximum Conductor Size | 18mm | |
| Safety Category Level | CAT III | |
| Non-Contact Voltage Detector | Yes | |
| Display Type | LCD | |
| Safety Category Voltage | 600V | |
| Power Source | Battery | |
| Maximum Temperature Measurement | 50°C | |
| Battery Type | AA | |
| Maximum AC Current Measurement | 200A | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Product Type Clamp Meter | ||
Maximum DC Current Measurement 200A | ||
Resistance Resolution 100mΩ | ||
Maximum AC Voltage Measurement 600V ac | ||
Maximum DC Voltage Measurement 600V dc | ||
Maximum Resistance Measurement 6kΩ | ||
Model Number 365 | ||
Maximum Jaw Opening 18mm | ||
AC Voltage Resolution 100mV ac | ||
DC Voltage Resolution 100 mV dc | ||
Minimum Operating Temperature -10°C | ||
AC Voltage Accuracy ±1.5 % rdg + 5 Digits | ||
AC Current Resolution 100mA | ||
Resistance Measurement Accuracy ± 1 % ± 5 Digits | ||
Clamp Meter Type AC/DC Clamp Meter | ||
DC Voltage Accuracy ±1 % rdg + 5 Digits | ||
DC Current Resolution 100mA | ||
DC Current Accuracy ±2 % rdg + 5 Digits | ||
AC Current Accuracy ±2 % rdg + 5 Digits | ||
Maximum Operating Temperature 50°C | ||
Length 225mm | ||
Weight 275g | ||
Width 65mm | ||
Standards/Approvals CAN/CSA-C22.2 No. 61010-1-04, UL 61010-1:2004 | ||
Height 46mm | ||
True RMS Yes | ||
Functions Measured Resistance, Continuity, DC Voltage, AC Current, AC Voltage, DC Current | ||
Maximum Conductor Size 18mm | ||
Safety Category Level CAT III | ||
Non-Contact Voltage Detector Yes | ||
Display Type LCD | ||
Safety Category Voltage 600V | ||
Power Source Battery | ||
Maximum Temperature Measurement 50°C | ||
Battery Type AA | ||
Maximum AC Current Measurement 200A | ||
- COO (Country of Origin):
- CN
Fluke Clamp Meter, 18mm Maximum Conductor Size, 200A Maximum AC Current Measurement - 3790607
Features and Benefits:
• 200.0A maximum current capacity for high-load circuits
• 600V maximum voltage range for mains-level testing
• 18mm jaw opening for single-conductor clamping
• NCV function for non-contact live conductor detection
• CAT III 600V safety rating for distribution-level environments
Applications
• Ideal for commissioning mains distribution boards
• Used for verifying DC current in battery systems
• Can be used for insulation continuity checks during maintenance
• Used on site testing where safe non-contact checks are needed
What battery type does it use and how is it powered?
What display and readout detail does it provide?
What temperature range is permissible for operation?
What accuracy can be expected for AC voltage measurements?
What is the maximum resistance and its resolution?
Related links
- Fluke 902 FC Clamp Meter, 200 μA 600 A 600 V dc 600 V ac CAT III Non-Contact Voltage Detector
- RS PRO ICMA7-4 Clamp Meter 200 A 600 V dc 600 V ac CAT III Non-Contact Voltage Detector
- Fluke 323 Clamp Meter 400 A 600 V dc 600 V ac CAT IV, CAT III Non-Contact Voltage Detector
- Fluke 355 Clamp Meter CAT III Non-Contact Voltage Detector
- Fluke A3000 FC Clamp Meter, 400 mA 400 A 600 V dc 600 V ac CAT III Non-Contact Voltage Detector
- Fluke 325 Clamp Meter 400 A 600 V ac CAT IV, CAT III Non-Contact Voltage Detector
- Extech EX623A Clamp Meter, 600 A dc 600 A ac 600 V dc 600 V ac CAT III Non-Contact Voltage Detector
- Megger DCM310 Clamp Meter 400 A 600 V dc 600 V ac CAT III Non-Contact Voltage Detector