Better World
Schneider Electric Auxiliary Contact, A9C, DIN Rail, 12V ac, 48 V ac, A9C15419
- RS Stock No.:
- 791-2852
- Mfr. Part No.:
- A9C15419
- Manufacturer:
- Schneider Electric
Subtotal (1 unit)*
SGD207.97
(exc. GST)
SGD226.69
(inc. GST)
Stock information currently inaccessible - Please check back later
Units | Per unit |
|---|---|
| 1 + | SGD207.97 |
*price indicative
Better World
Our Better World range features products that make it easy for you to make a greener product choice you can trust. Click here to find out more.
- RS Stock No.:
- 791-2852
- Mfr. Part No.:
- A9C15419
- Manufacturer:
- Schneider Electric
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Schneider Electric | |
| Product Type | Auxiliary Contact | |
| Series | A9C | |
| Mount Type | DIN Rail | |
| Terminal Type | Tunnel | |
| Contact Voltage | 12, 48V ac | |
| Rated Insulation Voltage Ui | 440V | |
| Mechanical Durability | 5000000Cycles | |
| Minimum Operating Temperature | -20°C | |
| Mounting Location | Vertical | |
| Operational Current Ie | 3A | |
| Maximum Operating Temperature | 50°C | |
| Standards/Approvals | IEC 1095, EN 61095, EN 60669-2-2, IEC/EN 60947-5-1 | |
| Better World Product | Yes | |
| Select all | ||
|---|---|---|
Brand Schneider Electric | ||
Product Type Auxiliary Contact | ||
Series A9C | ||
Mount Type DIN Rail | ||
Terminal Type Tunnel | ||
Contact Voltage 12, 48V ac | ||
Rated Insulation Voltage Ui 440V | ||
Mechanical Durability 5000000Cycles | ||
Minimum Operating Temperature -20°C | ||
Mounting Location Vertical | ||
Operational Current Ie 3A | ||
Maximum Operating Temperature 50°C | ||
Standards/Approvals IEC 1095, EN 61095, EN 60669-2-2, IEC/EN 60947-5-1 | ||
Better World Product Yes | ||
Schneider Electric A9C Series Auxiliary Contact, 3A Operational Current, 440V Rated Insulation Voltage - A9C15419
This auxiliary contact provides timed switching functionality for control circuits and is designed to mount on DIN-rail systems in electrical panels. It operates with impulse and maintained control voltages and is intended for use alongside thermal protection and switching devices in small commercial and residential installations.
Features & Benefits
• Time delay selectable from 2s up to 10h offering flexible sequencing
• Control voltage accepts 24 to 110V DC or 24 to 240V AC enabling broad compatibility
• Output inrush 3A with 0.2A hold current for reliable signalling
• Insulation rating 440V to suit medium-voltage control circuits
• Mechanical endurance 5,000,000 cycles for long service life
• Designed for vertical DIN-rail mounting to save panel space
• Control voltage accepts 24 to 110V DC or 24 to 240V AC enabling broad compatibility
• Output inrush 3A with 0.2A hold current for reliable signalling
• Insulation rating 440V to suit medium-voltage control circuits
• Mechanical endurance 5,000,000 cycles for long service life
• Designed for vertical DIN-rail mounting to save panel space
Applications
• Suitable for integration with thermal overload relays in motor control
• Ideal for sequencing auxiliary contacts in automation panels
• used with contactors in small commercial electrical distribution
• Can be used for delayed signalling in residential control circuits
• Ideal for sequencing auxiliary contacts in automation panels
• used with contactors in small commercial electrical distribution
• Can be used for delayed signalling in residential control circuits
What Terminal types are provided for incoming and outgoing wiring?
Input conductors connect via tunnel-type terminals supporting 2.5mm2 flexible or 1.5mm2 solid conductors while outputs use yellow clip connections.
How does the device perform under varying ambient temperatures?
It is specified to operate between -20°C and 50°C and stores safely within a wider temperature band.
What ingress protection and overvoltage capability does it offer?
The enclosure is rated IP20 and the unit meets overvoltage category III with a 4kV rated impulse withstand.
What mounting and installation details should installers note?
The unit occupies two 9mm pitches and is fixed to the left of compatible devices on a DIN rail using a standard 0.8N·m Terminal tightening torque.
Are there any packaging or origin details relevant for procurement?
It is supplied as single-piece packaging items and is manufactured in France.
Related links
- Schneider Electric Auxiliary Contact DIN Rail 24 V dc A9C15915
- Schneider Electric Auxiliary Contact 2 NO DIN Rail 130 V dc 240V ac, A9C15916
- Schneider Electric Auxiliary Contact 2 CO DIN Rail A9C15919
- Schneider Electric Auxiliary Contact 2 CO DIN Rail A9C15920
- Schneider Electric Auxiliary Contact 2 CO DIN Rail A9A26919
- Schneider Electric Auxiliary Contact Acti9 Auxiliaires 6 A A9N26959
- Schneider Electric Auxiliary Contact Module Acti9 A9C15412
- Schneider Electric Auxiliary Contact 2 CO DIN Rail 130 V dc A9N26929