SICK i110 Safety Interlock Switch, Power, Fibreglass Reinforced Thermoplastic, Electromagnetic

Subtotal (1 unit)*

SGD566.98

(exc. GST)

SGD618.01

(inc. GST)

Add to Basket
Select or type quantity
Stocked by manufacturer
  • Ready to ship from 04 December 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
1 +SGD566.98

*price indicative

RS Stock No.:
285-9569
Mfr. Part No.:
i110-E0313S06
Manufacturer:
SICK
Find similar products by selecting one or more attributes.
Select all

Brand

SICK

Lock Style

Power

Product Type

Safety Interlock Switch

Lock Type

Electromagnetic

Actuator Included

No

Safety Contacts

2 NC

Housing Material

Fibreglass Reinforced Thermoplastic

Series

i110

IP Rating

IP67

Switch Contact Current

4A

Contact DC Voltage

24V dc

Contact AC Voltage

230V ac

Minimum Operating Temperature

-20°C

Hazardous Area Certification

No

Maximum Operating Temperature

55°C

Number of Head Directions

5

Standards/Approvals

IEC 60529

Length

190mm

Depth

40mm

Width

42mm

COO (Country of Origin):
DE

SICK i110 Series Safety Interlock Switch, 4A Switch Contact Current, IP67 - i110-E0313S06


This safety interlock switch provides electro-mechanical access control for machinery guards, using a power-to-lock electromagnetic mechanism and designed for industrial environments. It is enclosed in a glass-fibre reinforced thermoplastic housing and intended for connection via three M20 cable glands. The unit operates with diagnostic-capable individual wiring and requires an actuator (not supplied) to function.

Features and Benefits:


• 2NC safety contacts deliver monitored normally-closed switching integrity
• 4A contact current supports 230V AC and 24V DC applications
• Power-to-lock principle provides 2,500N maximum locking force
• IP67 enclosure rating enables use in harsh, contaminated settings
• Five actuation directions allow flexible guard alignment

Applications


• Suitable for guarding on automated production lines
• Ideal for integration with safety logic units for diagnostics
• Used with interlocked doors on material handling equipment
• Can be used for perimeter protection in machine cells
• Suitable for environments requiring dust and water resistance

What electrical interfaces are available for connection?


It uses electro-mechanical contacts with three M20 cable glands and accepts conductor sizes 0.34mm² to 1.5mm².

How does the device behave if an internal fault occurs?


The switch contains no internal fault detection and relies on the external safety-related logic unit for fault monitoring.

What are the thermal operating limits for duty planning?


The ambient operating and storage temperature range is -20°C to +55°C.

What mechanical lifecycle can be expected under small loads?


The device has a mechanical life of 1x10^5 switching cycles and a B10d Value of 5x10^6 switching cycles for small loads.