SICK TR4 Safety Interlock Switch, RFID, Vistal

Subtotal (1 unit)*

SGD427.22

(exc. GST)

SGD465.67

(inc. GST)

Add to Basket
Select or type quantity
Stocked by manufacturer
  • Ready to ship from 25 November 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
1 +SGD427.22

*price indicative

RS Stock No.:
285-9063
Mfr. Part No.:
TR4-SDM10PB
Manufacturer:
SICK
Find similar products by selecting one or more attributes.
Select all

Brand

SICK

Product Type

Safety Interlock Switch

Lock Style

RFID

Actuator Included

No

Safety Contacts

2

Housing Material

Vistal

Series

TR4

Switch Contact Current

200mA

Contact DC Voltage

24V dc

Contact AC Voltage

230V ac

IP Rating

IP69K, IP67

Minimum Operating Temperature

-25°C

Maximum Operating Temperature

70°C

Hazardous Area Certification

No

Length

88mm

Standards/Approvals

IEC 60529

Number of Head Directions

5

Width

25mm

Depth

20mm

COO (Country of Origin):
DO

SICK TR4 Series Safety Interlock Switch, 24V DC Supply, IP67 - TR4-SDM10PB


This safety interlock switch is a non-contact RFID device designed to monitor access points and protect personnel in industrial settings. It operates from a 24V DC supply and provides two safely monitored semiconductor outputs for integration into safety circuits. The unit is suited to control-cabinet wiring with diagnostic capability and is built to withstand harsh environments and routine industrial stresses.

Features and Benefits:


• SIL 3 safety level delivering high-integrity protection
• Category 4 safety enabling Advanced risk reduction
• PFHD 6.03e-10 offering quantifiable failure metrics
• 10m cable with long-run capability to 200m reducing wiring changes
• Self-monitoring OSSD outputs limiting external fault propagation

Applications


• Suitable for machine-guard monitoring in manufacturing lines
• Ideal for food-industry washdown environments requiring IP69K
• Used with safety controllers needing PL e performance
• Can be used for access control on automated cells
• Suitable for installations requiring vibration and shock resilience

What temperatures can it operate within?


It functions across an ambient range of -25°C to +70°C.

How are status indications provided on the device?


Built-in LEDs provide Visual status and diagnostic indication.

What electrical loads can the outputs drive?


Each semiconductor output supplies up to 200mA and accepts 24V DC control voltage.

How is the unit connected and what cable characteristics apply?


It uses a 10m PVC-sheathed cable, 6.5mm diameter, 0.25mm² conductors with specified bend radii.