Schneider Electric 4 Pole Residual Current Circuit Breaker, 63A iID, 300mA

Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): ES
Product Details

RCCB Acti9 iID

The Acti 9 iID DIN rail RCCBs, are fully coordinated with the iC60 MCBs to warranty an absolute people and equipment protection against electrocution, risk of fire and improved continuity of service.

iID residual current circuit breakers AC Type provide:

Protection of persons against electric shock by direct contact (≦ 30 mA).
Protection of persons against electric shock by indirect contact (≧ 100 mA).
Protection of installations against the risk of fire (300 mA or 500 mA).

iID residual current circuit breakers Asi Type provide:

Protection of persons against electric shock by direct contact (≦ 30 mA).
Protection of persons against electric shock by indirect contact (≧ 300 mA).
Protection of installations against the risk of fire (300 mA or 500 mA).
Increased immunity from electrical interference and polluted or corrosive environments.

Specifications
Attribute Value
Current Rating 63A
Number of Poles 4
Trip Sensitivity 300mA
Series iID
Rated AC Voltage 415V
Mounting Style DIN Rail Mount
3 In stock for delivery within 4 working days
Price Each
SGD 284.55
(exc. GST)
SGD 304.47
(inc. GST)
units
Per unit
1 +
SGD284.55
Related Products
RCBO's : DIN rail mounting with an operating ...
Description:
RCBO's : DIN rail mounting with an operating temperature range of -25 to +55 °C. Optimum frequency range of 50 to 60Hz. Compact AC DIN rail mount 2 and 4 Pole RCCB’sProtects against the effects of sinusoidal alternating earth fault ...
All-current-sensitive FI circuit breaker for detection of residual ...
Description:
All-current-sensitive FI circuit breaker for detection of residual AC currents, pulsating and smooth residual DC currentsIncreased operating reliability in networks with capacitive impedances based on adapted actuation characteristicSwitch handle and test button may be locked via handle lockTime-delayed disconnect ...
Function: protection against the effects of sinusoidal alternating ...
Description:
Function: protection against the effects of sinusoidal alternating and direct pulsating earth fault currents; protection against indirect contacts and additional protection against direct (with IΔn=30mA) contacts.,Application: residential, commercial, industrial.,Standard: IEC/EN 61008,Marking: according to EN 61008.
Acti9 iTG40 RCCBs limits wear and reduces voltage ...
Description:
Acti9 iTG40 RCCBs limits wear and reduces voltage drops, helping to prevent premature equipment aging and overheating. VisiTrip indicates only the faulty outgoer, allowing fast diagnosis, resolution, and re-closing loads for easier building management and reduced downtimeInsulation Voltage: 440 VacVoltage: ...