Siemens SENTRON Series Residual Current Circuit Breaker, 80 A, 4-Pole, 300 mA, Type F, 10 kA 400 V ac
- RS Stock No.:
- 211-9716
- Mfr. Part No.:
- 5SV3647-7
- Manufacturer:
- Siemens
Subtotal (1 unit)*
SGD1,845.80
(exc. GST)
SGD2,011.92
(inc. GST)
Stock information currently inaccessible - Please check back later
Units | Per unit |
|---|---|
| 1 + | SGD1,845.80 |
*price indicative
- RS Stock No.:
- 211-9716
- Mfr. Part No.:
- 5SV3647-7
- Manufacturer:
- Siemens
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Siemens | |
| Product Type | Residual Current Circuit Breaker | |
| Current Rating | 80 A | |
| Number of Poles | 4 | |
| Series | SENTRON | |
| Range | SENTRON | |
| Trip Sensitivity | 300mA | |
| Tripping Characteristics | Type F | |
| Mount Type | DIN Rail | |
| Standards/Approvals | UKCA, EAC, VDE, CE | |
| Terminal Type | Screw | |
| Width | 72 mm | |
| Height | 90mm | |
| Depth | 70mm | |
| Breaking Capacity | 10kA | |
| Reset Actuator Type | Toggle Switch | |
| Tripping Mechanism | Electromagnetic | |
| Rated AC Voltage | 400 V ac | |
| Break Time | Instantaneous | |
| Earth Leakage Protection Type | Type A | |
| Select all | ||
|---|---|---|
Brand Siemens | ||
Product Type Residual Current Circuit Breaker | ||
Current Rating 80 A | ||
Number of Poles 4 | ||
Series SENTRON | ||
Range SENTRON | ||
Trip Sensitivity 300mA | ||
Tripping Characteristics Type F | ||
Mount Type DIN Rail | ||
Standards/Approvals UKCA, EAC, VDE, CE | ||
Terminal Type Screw | ||
Width 72 mm | ||
Height 90mm | ||
Depth 70mm | ||
Breaking Capacity 10kA | ||
Reset Actuator Type Toggle Switch | ||
Tripping Mechanism Electromagnetic | ||
Rated AC Voltage 400 V ac | ||
Break Time Instantaneous | ||
Earth Leakage Protection Type Type A | ||
- COO (Country of Origin):
- DE
The Siemens Residual current operated circuit breaker has 4-pole and type Operating current is 80 A and trippening current 300 mA. Supply voltage is 400 V. The RCD is the residual current device for touch protection. Siemens offers a comprehensive portfolio of protection, switching, measuring and monitoring devices, distribution systems as well as switches and sockets for safe and efficient electrical infrastructure in buildings and industry.
Protection class IP IP20 if the distribution board is installed, with connected conductors
Silicon- free
Related links
- Siemens SENTRON Series Residual Current Circuit Breaker 4-Pole Type F, 10 kA 400 V ac
- Siemens SENTRON Series Residual Current Circuit Breaker 4-Pole Type F, 10 kA 400 V ac
- Siemens SENTRON Series Residual Current Circuit Breaker 2-Pole Type F, 10 kA 400 V ac
- Siemens SENTRON Series Residual Current Circuit Breaker 2-Pole Type F, 10 kA 400 V ac
- Siemens SENTRON Series Residual Current Circuit Breaker 4-Pole Type B, 10 kA 400 V ac
- Siemens SENTRON Series Residual Current Circuit Breaker 4-Pole Type A, 10 kA 400 V ac
- Siemens SENTRON Series Residual Current Circuit Breaker 2-Pole Type F, 10 kA 400 V ac
- Siemens SENTRON Series Residual Current Circuit Breaker 2-Pole Type F, 10 kA 400 V ac