Eaton Residential RCBO, 10 A Current Rating, 2-Pole, 30 mA Trip Sensitivity, Type B, AFDD Range, AFDD Range
- RS Stock No.:
- 146-2816
- Mfr. Part No.:
- 187168 AFDD-10/2/B/003-A
- Manufacturer:
- Eaton
Subtotal (1 unit)*
SGD359.71
(exc. GST)
SGD392.08
(inc. GST)
Add 1 unit to get free delivery
Temporarily out of stock
- Shipping from 15 April 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | SGD359.71 |
*price indicative
- RS Stock No.:
- 146-2816
- Mfr. Part No.:
- 187168 AFDD-10/2/B/003-A
- Manufacturer:
- Eaton
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Eaton | |
| Product Type | Residential RCBO | |
| Current Rating | 10 A | |
| Series | AFDD | |
| Range | AFDD | |
| Number of Poles | 2 | |
| Trip Sensitivity | 30mA | |
| Tripping Characteristics | Type B | |
| Mount Type | DIN Rail | |
| Rated AC Voltage | 240 V ac | |
| Terminal Type | Screw | |
| Earth Leakage Protection Type | AC | |
| Depth | 80mm | |
| Break Time | Instantaneous | |
| Breaking Capacity | 10kA | |
| Tripping Mechanism | Thermal Magnetic | |
| Standards/Approvals | RoHS, IEC | |
| Reset Actuator Type | Toggle Switch | |
| Select all | ||
|---|---|---|
Brand Eaton | ||
Product Type Residential RCBO | ||
Current Rating 10 A | ||
Series AFDD | ||
Range AFDD | ||
Number of Poles 2 | ||
Trip Sensitivity 30mA | ||
Tripping Characteristics Type B | ||
Mount Type DIN Rail | ||
Rated AC Voltage 240 V ac | ||
Terminal Type Screw | ||
Earth Leakage Protection Type AC | ||
Depth 80mm | ||
Break Time Instantaneous | ||
Breaking Capacity 10kA | ||
Tripping Mechanism Thermal Magnetic | ||
Standards/Approvals RoHS, IEC | ||
Reset Actuator Type Toggle Switch | ||
- COO (Country of Origin):
- CZ
Eaton Arc Fault Detection Device, 2 Pole, Type B - AFDD+ Series - AFDD-10/2/B/003-A
This AFDD (arc fault detection device) from Eaton breaks circuits when it detects electrical arcs or high-power discharges of electricity between two conductors. These faults are typically caused by loose or damaged wires and terminals, and can generate enough heat to cause a fire. As well as an AFDD, this multi-purpose device functions as an RCD (residual current device) to detect and prevent earth faults, and an MCB (miniature circuit breaker) for short circuit overloads.
• LED fault indicator signals the exact cause of the trip
• Green-to-red coloured switch indicators clearly show when device is on or off
• Yellow tripping test button lets you check switch is operational
How do I install this device?
Connect the neutral and line wires either way round into the bottom of the device and connect the load wires to the top.
How does the LED indicator work?
The LED side indicator is green in normal operation. When turned back on after a trip, a yellow light flashes between one and six times to indicate the cause. This tells you whether it is one of two series arc faults, a parallel arc fault, overvoltage, overheating or a wider system fault.
AFDD
Professional range of Eaton AFDD+ RCBOs for Type B distribution boards. The switch disconnectors are designed for general commercial building applications.
Electric Fire Protection Device
Note
Eaton formerly known as Moeller
Related links
- Eaton AFDD 2P Poles Type B, Eaton Moeller Range
- Eaton RCBO 2P Poles AFDD Range
- Eaton AFDD 2P Poles Type C, Eaton Moeller Range
- Eaton AFDD 2P Poles Type B, AFDD+ Range
- Eaton AFDD 2P Poles Type B, AFDD+ Range
- Eaton AFDD 2P Poles Type B, Eaton Moeller Range
- Eaton AFDD 2P Poles Type B, Eaton Moeller Range
- Eaton AFDD 2P Poles Type B, Eaton Moeller Range