Fluke 717 -850 mbar to 6.895 bar Pressure Calibrator
- RS Stock No.:
- 447-7713
- Mfr. Part No.:
- FLUKE-717 100G
- Manufacturer:
- Fluke
This image is representative of the product range
Subtotal (1 unit)*
SGD3,614.00
(exc. GST)
SGD3,939.26
(inc. GST)
FREE delivery for orders over $150, or create a business account to enjoy free delivery from just $28
Stocked by manufacturer
- Ready to ship from 06 July 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | SGD3,614.00 |
*price indicative
- RS Stock No.:
- 447-7713
- Mfr. Part No.:
- FLUKE-717 100G
- Manufacturer:
- Fluke
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Fluke | |
| Maximum Pressure Measurement | 6.895bar | |
| Product Type | Pressure Calibrator | |
| Battery Type | Alkaline | |
| Minimum Pressure Measurement | -850mbar | |
| Accuracy | ±0.015 % | |
| Resolution | 1 mbar | |
| Model Number | 717 | |
| Data Logging | No | |
| Current Loop Measurement | Yes | |
| Display Type | LCD | |
| Leak Testing | Yes | |
| Power Source | Battery | |
| Minimum Operating Temperature | -10°C | |
| Weight | 600g | |
| Maximum Operating Temperature | 55°C | |
| Length | 201mm | |
| Standards/Approvals | No | |
| Width | 98mm | |
| Height | 52mm | |
| Hazardous Area Certification | NO | |
| Select all | ||
|---|---|---|
Brand Fluke | ||
Maximum Pressure Measurement 6.895bar | ||
Product Type Pressure Calibrator | ||
Battery Type Alkaline | ||
Minimum Pressure Measurement -850mbar | ||
Accuracy ±0.015 % | ||
Resolution 1 mbar | ||
Model Number 717 | ||
Data Logging No | ||
Current Loop Measurement Yes | ||
Display Type LCD | ||
Leak Testing Yes | ||
Power Source Battery | ||
Minimum Operating Temperature -10°C | ||
Weight 600g | ||
Maximum Operating Temperature 55°C | ||
Length 201mm | ||
Standards/Approvals No | ||
Width 98mm | ||
Height 52mm | ||
Hazardous Area Certification NO | ||
RoHS Status: Exempt
- COO (Country of Origin):
- CN
Fluke Pressure Calibrator, 7 Bar Maximum Pressure Measurement, ±0.015% Accuracy - FLUKE-717 100G
This pressure calibrator is a handheld instrument for measuring and sourcing pneumatic pressure and mA loops in industrial environments. Designed for portability, it supports internal sensing for low-range tests and accepts external pressure modules for extended spans, while operating across typical workshop temperatures and humidities.
Features & Benefits
• ±0.015% accuracy delivers precise calibration results
• 0.1 mbar resolution enables fine pressure discrimination
• Measures from −850 mbar to 7 bar for wide pneumatic coverage
• Supplies 24V loop power while measuring mA for transmitter work
• LCD display with five digits provides clear numerical readout
• Battery operation offers field use without mains dependency
• 0.1 mbar resolution enables fine pressure discrimination
• Measures from −850 mbar to 7 bar for wide pneumatic coverage
• Supplies 24V loop power while measuring mA for transmitter work
• LCD display with five digits provides clear numerical readout
• Battery operation offers field use without mains dependency
**Applications**
• Suitable for bench calibration of pneumatic transmitters and gauges
• Ideal for on-site pressure verification and leak testing tasks
• Used with pressure modules to extend measurement to high pressures
• Can be used for commissioning current loop control systems
• Suitable for maintenance checks in automation and process plants
• Ideal for on-site pressure verification and leak testing tasks
• Used with pressure modules to extend measurement to high pressures
• Can be used for commissioning current loop control systems
• Suitable for maintenance checks in automation and process plants
What pressure media are compatible with the instrument?
Internal and module sensors accept non-corrosive gases and liquids
compatibility of external modules depends on their specific media ratings.
How does it handle higher pressure ranges?
Higher spans are achieved by attaching one of the manufacturers pressure modules which extend measurement capability to very high pressures per module specifications.
What environmental conditions limit use?
The unit operates between −10 °C and 55 °C and has specified relative humidity limits varying with temperature to maintain performance.
What power source and runtime should I expect?
It runs from a single 9V alkaline battery and battery life typically ranges from 4 to 20 hours depending on functions used.
Related links
- Fluke 717 -850 mbar to 20.68 bar Pressure Calibrator
- Fluke 718 -850 mbar to 6.895 bar Pressure Calibrator
- Fluke 719 -850 mbar to 8 bar Pressure Calibrator
- Fluke 719 -850 mbar to 2.4 bar Pressure Calibrator
- Fluke 718 -850 mbar to 20 bar Pressure Calibrator
- Fluke 717 0 psi to 10000 psi Pressure Calibrator
- Fluke 718 -850mbar to 7bar Pressure Calibrator
- Fluke 719PRO -0.8 bar to 2 bar Pressure Calibrator
