Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
- COO (Country of Origin):
- BG
Product Details
i430-Flexi-TF-II 6000A Flexible AC Current Probe
The i430-Flexi-TF-II flexible AC current probe is optimized for current measurement on thick and hard to reach conductors. The i430-Flexi-TF-II is a flexible AC current probe for use with the Fluke 430 series Power Quality Analyzers including Series II.
Measuring range: 0.5 to 6000 A ac
Bandwidth (-3 dB): 10 Hz to 10 kHz
Output signal: 86.6 mV at 1000A/50Hz (on 1 MΩ), 85.0 mV at 1000A/50Hz (on 50 kΩ)
Maximum non-destructive current: 100 kA (50/60 Hz)
Transducer length: 610 mm (24 in)
Transducer diameter: 7.5 mm (0.3 in)
Minimum bending radius: 38 mm (1.5 in)
Cable length from transducer to BNC: 2.5 m (98.4 in)
Complies with: IEC 61010-1: Pollution degree 2, IEC 61010-2-032: 1000V CAT III/ 600V CAT IV, IEC 61010-031
Bandwidth (-3 dB): 10 Hz to 10 kHz
Output signal: 86.6 mV at 1000A/50Hz (on 1 MΩ), 85.0 mV at 1000A/50Hz (on 50 kΩ)
Maximum non-destructive current: 100 kA (50/60 Hz)
Transducer length: 610 mm (24 in)
Transducer diameter: 7.5 mm (0.3 in)
Minimum bending radius: 38 mm (1.5 in)
Cable length from transducer to BNC: 2.5 m (98.4 in)
Complies with: IEC 61010-1: Pollution degree 2, IEC 61010-2-032: 1000V CAT III/ 600V CAT IV, IEC 61010-031
Supplied with
Instruction Sheet
FLUKE Flexible Current Sensor, 10Hz to 7kHz Bandwidth, ±1% Basic Accuracy - I430-FLEXI-TF-II
Get precise measurements at your fingertips with this flexible current sensor from FLUKE. It's designed to read current values on thick and hard-to-reach conductors. Thanks to a current measurement range between 0.5 and 6000A AC, you can depend on it to provide reliable results across a wide spectrum of conditions. An output signal of 86.6mV at 1000A/50Hz means the unit can easily connect to various measuring devices, such as oscilloscopes and multimeters. For efficiency, this sensor has a maximum non-destructive current of 100kA at 50/60Hz.
Features & Benefits
Minimum bending radius of 38mm means it's a flexible fit for awkward spaces
Broad operating temperature range between -20°C and +70°C makes it suitable for harsh environments
Operating altitude of 3000m for use in elevated setups
Broad operating temperature range between -20°C and +70°C makes it suitable for harsh environments
Operating altitude of 3000m for use in elevated setups
Applications
Facilities management
Healthcare industry
Power distribution
Data centres
Healthcare industry
Power distribution
Data centres
How easy is it to install this current sensor?
As it doesn't need batteries or an external power source, setup of the unit is a cinch. Just connect it to the desired input on a power quality analyser in the FLUKE 430 series (530-0995).
Specifications
Attribute | Value |
Accessory Type | Rogowski Coil |
For Use With | Fluke 433/434/435/434-II/435-II/437-II |