Siemens PLC Cable for Use with IMATIC ET200 and SCALANCE XP-200

Subtotal (1 unit)*

SGD412.24

(exc. GST)

SGD449.34

(inc. GST)

Add to Basket
Select or type quantity
Stocked by manufacturer
  • Ready to ship from 25 May 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
1 +SGD412.24

*price indicative

TH - smart automation - PDP
RS Stock No.:
265-8933
Mfr. Part No.:
6XV18708AN40
Manufacturer:
Siemens
Find similar products by selecting one or more attributes.
Select all

Brand

Siemens

Product Type

PLC Cable

Accessory Type

Connecting Cable

For Use With

IMATIC ET200 and SCALANCE XP-200

IP Rating

IP67, IP65

Standards/Approvals

CE, EAC, RoHS, UL

Hazardous Area Certification

NO

COO (Country of Origin):
DE

Siemens PLC Cable, IP67 - 6XV18708AN40


This PLC cable connects industrial Ethernet stations and field devices in industrial automation environments. It is a flexible, factory-terminated Ethernet lead with two D‑coded 4‑pole M12 plugs configured for a 180° cable outlet. The assembly is intended for use with IMATIC ET200 and SCALANCE XP-200 equipment and is suitable for use where ingress protection to IP65/IP67 is required.

Features & Benefits


• 40m pre-assembled length delivers immediate installation readiness
• 100 Ω characteristic impedance ensures consistent signal integrity
• 0.063 dB/m attenuation at 10MHz preserves low-frequency transmission
• 0.213 dB/m attenuation at 100MHz supports higher bandwidths
• Drag-chain rated for 3 million cycles enables long service life
• Operating temperature range −25 to +75°C allows use in harsh environments

**Applications**


• Suitable for linking IMATIC ET200 modules in factory cells
• Ideal for connecting SCALANCE XP-200 switches in network segments
• Used with M12 fieldbus connector cable installations in machine rooms
• Can be used for outdoor cabinet-to-field-device Ethernet runs requiring waterproof connections

What shielding does it use to reduce interference?


The cores are covered by overlapped aluminium-clad foil Plus a braided tin‑plated copper screen to limit electromagnetic interference.

How Durable is the cable jacket for industrial exposure?


The outer sheath is PVC with conditional resistance to mineral oil and grease and demonstrated UV resistance for radiological exposure.

Which electrical ratings apply for routine operation?


The cable has an RMS operating voltage of 80V and a loop resistance up to 120 mΩ/m as specified for continuity and safety considerations.

How is the plug secured and coded for Ethernet?


Each M12 connector is D‑coded and uses a screw interlock for reliable mechanical retention in field installations.