Pico Technology TA Series TA043 Oscilloscope Probe, Differential Type, 100 MHz, BNC Connector

Subtotal (1 unit)*

SGD1,055.11

(exc. GST)

SGD1,150.07

(inc. GST)

Add to Basket
Select or type quantity
In Stock
  • Plus 23 unit(s) shipping from 16 March 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
1 +SGD1,055.11

*price indicative

RS Stock No.:
898-6741
Mfr. Part No.:
TA043
Manufacturer:
Pico Technology
Find similar products by selecting one or more attributes.
Select all

Brand

Pico Technology

Probe Type

Differential

Product Type

Oscilloscope Probe

Bandwidth

100MHz

Maximum Common Mode Input Voltage

700V

Connector Type

BNC

Model Number

TA043

Number of Probes

2

Safety Category Level

CAT III

Safety Category Voltage

1000V

Series

TA

Rise Time

3.5ns

Standards/Approvals

IEC 1010.2 031, IEC 1010.1

COO (Country of Origin):
TW

Pico Technology Oscilloscope Probe


The Pico Technology TA043 oscilloscope probe is an active differential probe, suitable for high common-mode voltage measurement applications up to ±700V. It can be used with a signal speed of up to 100MHz. This differential probe extends the functionality of standard single-ended input oscilloscopes to allow a safe and accurate method of making high voltage differential measurements.

By selecting attenuation ratio 1:10, this oscilloscope probe can measure signals below 70V to get higher resolution and less noise. Otherwise, set the attenuation to 1:100.

Features and Benefits


Bandwidth is DC to 100MHz (–3dB)

Attenuation ratio is 10:1/100:1

Accuracy is ±2%

Input impedance is 4Mohm ll7pF each side to ground

Differential range is (10:1) ±70V (DC + peak AC) or 70VRMS

Maximum differential is (100:1) ±700V (DC + peak AC) or 500VRMS

Common mode range is ±700V (DC + peak AC) or 500VRMS (10:1 & 100:1)

Absolute maximum voltage is ±1000VRMS CATIII (10:1 & 100:1)

Swing is ±7V into 50Kohm load

Offset (typical) is <±5mV

Noise (typical) is 0.9mVRMS

Source impedance is 50

CMRR (typical) is 85dB at 50Hz and 55dB at 1MHz

Ambient operating temperature ranges between -10°C and 40°C

Power requirement 4xAA cells or 6VDC/200mA mains adaptor or regulated 9VDC/120mA mains adaptor

Applications


Safe measurement in power circuit

Acquisition of low speed balanced differential signals found in serial communication buses

Transients in switching power supplies, inverters and motor drives, electronic ballasts and CRT displays

Signals in the milliV range from sensors and other instrumentation

Certifications


IEC-1010.1

IEC-1010.2-031 CAT III

Pollution Degree 2.