Broadcom Optocoupler, Surface Mount, 8-Pin
- RS Stock No.:
- 239-9283
- Mfr. Part No.:
- ACNT-H79B-000E
- Manufacturer:
- Broadcom
This image is representative of the product range
Bulk discount available
Subtotal (1 tube of 80 units)*
SGD1,190.56
(exc. GST)
SGD1,297.68
(inc. GST)
FREE delivery for orders over $150, or create a business account to enjoy free delivery from just $28
In Stock
- 400 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit | Per Tube* |
|---|---|---|
| 80 - 320 | SGD14.882 | SGD1,190.56 |
| 400 - 720 | SGD14.51 | SGD1,160.80 |
| 800 - 1520 | SGD14.147 | SGD1,131.76 |
| 1600 + | SGD13.793 | SGD1,103.44 |
*price indicative
- RS Stock No.:
- 239-9283
- Mfr. Part No.:
- ACNT-H79B-000E
- Manufacturer:
- Broadcom
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Broadcom | |
| Product Type | Optocoupler | |
| Mount Type | Surface Mount | |
| Number of Channels | 1 | |
| Number of Pins | 8 | |
| Typical Rise Time | 1.7μs | |
| Maximum Input Current | 230mA | |
| Minimum Operating Temperature | -40°C | |
| Maximum Operating Temperature | 105°C | |
| Standards/Approvals | RoHS | |
| Typical Fall Time | 1.7μs | |
| Series | ACNT-H79B | |
| Automotive Standard | No | |
| Select all | ||
|---|---|---|
Brand Broadcom | ||
Product Type Optocoupler | ||
Mount Type Surface Mount | ||
Number of Channels 1 | ||
Number of Pins 8 | ||
Typical Rise Time 1.7μs | ||
Maximum Input Current 230mA | ||
Minimum Operating Temperature -40°C | ||
Maximum Operating Temperature 105°C | ||
Standards/Approvals RoHS | ||
Typical Fall Time 1.7μs | ||
Series ACNT-H79B | ||
Automotive Standard No | ||
- COO (Country of Origin):
- PH
The Broadcom ACNT-H79B isolation amplifiers are designed for current and voltage sensing in electronic power converters for applications including motor drives and renewable energy systems. In a typical motor drive implementation, current flows through an external resistor and the resulting analog voltage drop is sensed by the isolation amplifier. A differential output voltage that is proportional to the current is created on the other side of the optical isolation barrier.
±05% gain accuracy (ACNT-H79B)
–50 ppm/°C low gain drift
06-mV input offset voltage
005% excellent linearity
60-dB SNR
200-kHz wide bandwidth (Typ)
–40°C to +105°C operating temperature range
Advanced sigma-delta (-) A/D modulation technology
15-mm stretched SO-8 package
05-mm distance through insulation (DTI)
15-kV/μs common-mode transient immunity