Fluke 116/62 MAX+ Multimeter Kit Multimeter Kit

Currently unavailable
Sorry, we don't know when this will be back in stock.
SG-PDP-Fluke
RS Stock No.:
785-0704
Distrelec Article No.:
110-74-931
Mfr. Part No.:
116/62 MAX+
Manufacturer:
Fluke
Find similar products by selecting one or more attributes.
Select all

Brand

Fluke

Product Type

Multimeter Kit

Model Number

116/62 MAX+

Application

Industrial

Kit Contents

Infrared Thermometers, Probes, Case, Multimeter

Kit Type

Multimeter Kit

Standards/Approvals

EN/IEC 610101: 2001, UL, CSA, EN 608251 Class II, FDA, CE, VDE, TUV

RoHS Status: Exempt

COO (Country of Origin):
MY

Fluke Multimeter Kit, 10A Current, Industrial Application - F1UKE11662MAX


This multimeter kit provides a portable toolkit for industrial electrical measurement and temperature checks in professional environments. Supplied with infrared thermometers, probes, a protective case and a Compact digital multimeter, it is intended for field and workshop use where voltage, current, resistance and temperature readings are required.

Features and Benefits:


• 10A input rating enables measurement of higher current loads
• True-rms measurement supports accurate AC readings under distortion
• 600V maximum between any Terminal and earth for broad coverage
• 6,000-count display updates 4/sec for readable, responsive readings
• 9V alkaline battery offers long run time of approximately400hours

Applications


• Suitable for industrial maintenance and plant electrical troubleshooting
• Ideal for HVAC temperature diagnostics with infrared thermometers
• Used for on-site testing of distribution circuits up to600V
• Can be used for commissioning and functional checks of electrical equipment
• Appropriate for portable test routines where a robust case is required

What safety ratings apply to the instruments in the kit?


The instruments meet IEC61010-1 and are rated for CATIII600V with Pollution Degree2.

Which approvals confirm regulatory compliance for industrial environments?


Certifications include UL, CSA, CE, VDE, TUV and EN60825-1 ClassII for applicable components.

How does the kit handle surge protection on the current input?


Fuse protection for the A input uses an 11A,1000V fuse with high interrupt rating for models so equipped.

What environmental limits affect instrument operation?


Operating temperature range is -10°C to +50°C with humidity limits varying by temperature up to90% at35°C.

What input impedance and noise rejection can users expect on voltage ranges?


DC volts input impedance exceeds10MΩ with common-mode rejection >100dB at dc and >60dB at50/60Hz.