SICK LFP Cubic Series Guided Radar Level Sensor, Vertical, Polytetrafluoroethylene, Housing PBT
- RS Stock No.:
- 794-3392
- Mfr. Part No.:
- LFP2000-A4NMB
- Manufacturer:
- SICK
Subtotal (1 unit)*
SGD882.57
(exc. GST)
SGD962.00
(inc. GST)
FREE delivery for orders over $150, or create a business account to enjoy free delivery from just $28
In Stock
- Plus 1 unit(s) shipping from 04 May 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | SGD882.57 |
*price indicative
- RS Stock No.:
- 794-3392
- Mfr. Part No.:
- LFP2000-A4NMB
- Manufacturer:
- SICK
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | SICK | |
| Device Type | Guided Radar | |
| Product Type | Level Sensor | |
| Mount Type | Vertical | |
| Housing Material | PBT | |
| Cable Length | 1m | |
| Minimum Operating Temperature | -20°C | |
| Interface Type | IO-Link | |
| Maximum Operating Temperature | +60°C | |
| Maximum DC Voltage | 30V dc | |
| Maximum Current | 100mA | |
| Maximum Pressure | 10bar | |
| Gasket Material | Polytetrafluoroethylene | |
| Standards/Approvals | cULus | |
| Hazardous Area Certification | NO | |
| Series | LFP Cubic | |
| Select all | ||
|---|---|---|
Brand SICK | ||
Device Type Guided Radar | ||
Product Type Level Sensor | ||
Mount Type Vertical | ||
Housing Material PBT | ||
Cable Length 1m | ||
Minimum Operating Temperature -20°C | ||
Interface Type IO-Link | ||
Maximum Operating Temperature +60°C | ||
Maximum DC Voltage 30V dc | ||
Maximum Current 100mA | ||
Maximum Pressure 10bar | ||
Gasket Material Polytetrafluoroethylene | ||
Standards/Approvals cULus | ||
Hazardous Area Certification NO | ||
Series LFP Cubic | ||
SICK LFP Cubic Series Level Sensor, 1m Cable Length, Vertical Mount Type - LFP2000-A4NMB
This level sensor is a guided radar device designed for vertical mounting to monitor liquid levels in industrial environments. It connects via IO-Link for digital communication and is housed in a Durable plastic PBT enclosure with a polytetrafluoroethylene gasket to resist contact with process media. The unit operates across a wide temperature range and withstands moderate process pressures, making it suitable for integration into automated measurement and control systems.
Features and Benefits:
• IO-Link Interface enables seamless digital integration and diagnostics
• Guided radar principle provides dependable level detection performance
• Operating range from -20°C to +60°C supports varied plant conditions
• Pressure tolerance up to 10 bar allows use in pressurised vessels
• Low current consumption at 100mA reduces load on supply circuits
• Supplied with a 1m cable for immediate connection to control hardware
• Guided radar principle provides dependable level detection performance
• Operating range from -20°C to +60°C supports varied plant conditions
• Pressure tolerance up to 10 bar allows use in pressurised vessels
• Low current consumption at 100mA reduces load on supply circuits
• Supplied with a 1m cable for immediate connection to control hardware
Applications
• Suitable for tank level monitoring in automation systems
• Ideal for use in electrical control panels requiring digital sensors
• Used with process vessels operating under moderate pressure
• Can be used for liquid level feedback to PLCs via IO-Link
• Suitable for retrofitting Compact measurement points in machinery
• Ideal for use in electrical control panels requiring digital sensors
• Used with process vessels operating under moderate pressure
• Can be used for liquid level feedback to PLCs via IO-Link
• Suitable for retrofitting Compact measurement points in machinery
What electrical supply limitations should I consider?
The sensor is rated for a maximum DC voltage of 30V and draws up to 100mA during operation, so ensure your supply and wiring meet these limits.
How should the sensor be installed in relation to Vessel orientation?
It is designed for vertical mounting
install perpendicular to the liquid surface for accurate guided radar measurements.
What approvals support installation in industrial sites?
The unit carries cULus approval, indicating conformity with applicable North American safety standards for electrical equipment.
Which materials contact the process medium?
The sealing is MADE from polytetrafluoroethylene and the outer enclosure is plastic PBT, providing chemical compatibility and protection for internal components.
Related links
- SICK LFP Cubic Series Guided Radar Level Radar Polytetrafluoroethylene, Housing Polybutylene Terephthalate
- SICK LFP Cubic Series Guided Radar Level Radar Vertical Housing Plastic
- SICK LFP Inox Series Guided Radar Level Sensor Polytetrafluoroethylene, Housing Polybutylene Terephthalate
- SICK LFP Inox Series Guided Radar Level Radar Polyetheretherketone, Housing Stainless Steel
- SICK LFP Inox Series Guided Radar Level Radar Vertical Fluorelastomer
- SICK LFP Series TDR Level Sensor Level Sensor, Housing Plastic Polybutylene Terephthalate
- Flowline EchoWave Series Guided Radar Level Sensor Level Radar Housing Aluminium
- SICK LFP Inox Series Sensor Level Radar Polyetheretherketone, Housing Stainless Steel