HARTING Heavy Duty Power Connector Insert, 10A, 0916 Series Male, 42 Contacts
- RS Stock No.:
- 144-4238
- Mfr. Part No.:
- 09162423001
- Manufacturer:
- HARTING
Bulk discount available
View bulk pricing optionsSubtotal (1 unit)*
SGD80.95
(exc. GST)
SGD88.24
(inc. GST)
FREE delivery for orders over $150, or create a business account to enjoy free delivery from just $28
In Stock
- 9 unit(s) ready to ship from another location
- Plus 15 unit(s) shipping from 22 June 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 - 9 | SGD80.95 |
| 10 - 24 | SGD80.47 |
| 25 - 74 | SGD79.27 |
| 75 - 224 | SGD75.71 |
| 225 + | SGD65.54 |
*price indicative
- RS Stock No.:
- 144-4238
- Mfr. Part No.:
- 09162423001
- Manufacturer:
- HARTING
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | HARTING | |
| Product Type | Heavy Duty Power Connector Insert | |
| Current Rating | 10A | |
| Series | 0916 | |
| Sub Type | Connector Insert | |
| Connector Gender | Male | |
| For Use With | Heavy Duty Power Connector | |
| Pole Format | 42 | |
| Number of Rows | 6 | |
| Voltage | 250V | |
| Mount Type | Cable | |
| Standards/Approvals | IEC 60664-1 | |
| Number of Contacts | 42 | |
| Manufacturer Size Code | 10B | |
| Thread Size | M3 x 10 | |
| Orientation | Straight | |
| Minimum Wire Size mm² | 0.14mm² | |
| Maximum Wire Size mm² | 2.5mm² | |
| Select all | ||
|---|---|---|
Brand HARTING | ||
Product Type Heavy Duty Power Connector Insert | ||
Current Rating 10A | ||
Series 0916 | ||
Sub Type Connector Insert | ||
Connector Gender Male | ||
For Use With Heavy Duty Power Connector | ||
Pole Format 42 | ||
Number of Rows 6 | ||
Voltage 250V | ||
Mount Type Cable | ||
Standards/Approvals IEC 60664-1 | ||
Number of Contacts 42 | ||
Manufacturer Size Code 10B | ||
Thread Size M3 x 10 | ||
Orientation Straight | ||
Minimum Wire Size mm² 0.14mm² | ||
Maximum Wire Size mm² 2.5mm² | ||
- COO (Country of Origin):
- DE
Harting Han DD HMC Series Heavy Duty Power Connector Insert, 10A Current Rating, 250V Voltage - 9162423001
This heavy-duty power connector insert is a cable-mounted, multi-contact solution designed for industrial electrical connections where compact, high-density power distribution is required. It provides a straightforward means to connect multiple circuits within machinery and control equipment, offering a straight orientation and male contact arrangement suitable for integration into robust connector housings.
Features & Benefits
• 42 contacts deliver high-density power distribution and simplified wiring
• Rated for 10A to support moderate current circuits in automation systems
• Voltage rating of 250V to accommodate common industrial supply levels
• Accepts conductors from 0.14–2.5mm² to cover fine to mid-size cables
• Cable-mounted design enables secure strain relief in panel-to-equipment runs
• Complies with IEC 60664-1 for reinforced insulation performance
• Rated for 10A to support moderate current circuits in automation systems
• Voltage rating of 250V to accommodate common industrial supply levels
• Accepts conductors from 0.14–2.5mm² to cover fine to mid-size cables
• Cable-mounted design enables secure strain relief in panel-to-equipment runs
• Complies with IEC 60664-1 for reinforced insulation performance
**Applications**
• Suitable for power distribution in automated assembly machinery
• Ideal for connection blocks in control cabinets and motor drives
• Used with heavy-duty connector shells for mobile plant interfaces
• Can be used for machine tool power and auxiliary circuit links
• Ideal for connection blocks in control cabinets and motor drives
• Used with heavy-duty connector shells for mobile plant interfaces
• Can be used for machine tool power and auxiliary circuit links
How is the insert arranged internally for multiple circuits?
It uses a 6-row pole layout providing 42 individual contact positions in a straight orientation for orderly conductor allocation.
What conductor sizes can be terminated reliably?
Termination accepts a minimum of 0.14mm² up to a maximum of 2.5mm² enabling both signal and power conductors where mid-range cross-sections are required.
Which mounting method does it require for installation?
The insert is intended for cable mounting, allowing it to be fitted into a corresponding heavy-duty connector Shell and secured within the cable assembly.
What contact gender and pole format does it provide?
It is fitted with male contacts arranged across 42 poles, suitable for mating with compatible female counterparts.
Related links
- HARTING Heavy Duty Power Connector Insert 0916 Series Female, 42 Contacts
- HARTING Heavy Duty Power Connector Insert HAN DD Series Male, 42 Contacts
- HARTING Heavy Duty Power Connector Insert 0916 Series Female, 24 Contacts
- HARTING Heavy Duty Power Connector Insert 0916 Series Male, 24 Contacts
- HARTING Heavy Duty Power Connector Insert 0916 Series Female, 108 Contacts
- HARTING Heavy Duty Power Connector Insert 0916 Series Male, 108 Contacts
- HARTING Heavy Duty Power Connector Insert 0916 Series Male, 72 Contacts
- HARTING Heavy Duty Power Connector Insert 0916 Series Female, 72 Contacts
