Lascar EL-CC-1-002 Temperature Data Logger, USB
- RS Stock No.:
- 910-7062
- Mfr. Part No.:
- EL-CC-1-002
- Manufacturer:
- Lascar
Bulk discount available
Subtotal (1 unit)*
SGD26.42
(exc. GST)
SGD28.80
(inc. GST)
FREE delivery for orders over $150, or create a business account to enjoy free delivery from just $28
In Stock
- 162 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 - 4 | SGD26.42 |
| 5 + | SGD21.73 |
*price indicative
- RS Stock No.:
- 910-7062
- Mfr. Part No.:
- EL-CC-1-002
- Manufacturer:
- Lascar
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Lascar | |
| Product Type | Data Logger | |
| Accuracy | ±0.5°C, ±0.5 °C | |
| Model Number | EL-CC-1-002 | |
| Measurement Parameters | Temperature | |
| Number of Channels | 1 | |
| Interface Type | USB | |
| Data Logger Type | Temperature | |
| Power Source | Battery | |
| IP Rating | IP67 | |
| Minimum Operating Temperature | -30°C | |
| Maximum Operating Temperature | 60°C | |
| Width | 48 mm | |
| Length | 67mm | |
| Hazardous Area Certification | No | |
| Standards/Approvals | No | |
| Display Type | LCD | |
| Alarm | Yes | |
| Number of Readings per Channel | 32600 | |
| Battery Life | 1year | |
| Battery Type | Non-Replaceable | |
| Select all | ||
|---|---|---|
Brand Lascar | ||
Product Type Data Logger | ||
Accuracy ±0.5°C, ±0.5 °C | ||
Model Number EL-CC-1-002 | ||
Measurement Parameters Temperature | ||
Number of Channels 1 | ||
Interface Type USB | ||
Data Logger Type Temperature | ||
Power Source Battery | ||
IP Rating IP67 | ||
Minimum Operating Temperature -30°C | ||
Maximum Operating Temperature 60°C | ||
Width 48 mm | ||
Length 67mm | ||
Hazardous Area Certification No | ||
Standards/Approvals No | ||
Display Type LCD | ||
Alarm Yes | ||
Number of Readings per Channel 32600 | ||
Battery Life 1year | ||
Battery Type Non-Replaceable | ||
- COO (Country of Origin):
- CN
Lascar EL-CC-1 Cold Chain, Chilled Goods, Data Loggers
Lascar EL-CC-1 data loggers are cost-effective, multi-use monitoring instruments for use at all stages of the cold chain process. There is a choice of 3 models: chilled goods, EL-CC-1-001 ( 910-7068 ) alarms high 8 °C, low 2 °C; frozen goods, EL-CC-1-002 ( 910-7062 ) alarms high -16 °C, low -20 °C; ripening goods EL-CC-1-003 ( 910-7071 ) alarms high 14 °C, low 12 °C. Each logger comes pre-configured for use in its particular application - users simply press the button to start logging. During a logging session, pressing the button will light up the status LEDs to give quick indication of whether temperature has exceeded an alarm condition at any point. When a session is completed, the user tears open the IP67-rated plastic wallet to reveal the USB connector and plugs this into a PC. Then the freely available EasyLog CC software for Windows is used to download and graph the data, following which the logger is primed for its next use. EL-CC-1 applications include transportation, fridge/freezer monitoring, food & drink, building & site monitoring, HVAC.
No set-up required - start logging with one press of a button
Pre-configured with appropriate sample rates and alarm thresholds for each application
Measurement range -30 to +60 °C (-22 to +140 °F)
Accuracy (overall error) ±0.5 °C (±1 °F) maximum
Resolution 0.1 °C (0.1 °F)
Readings 32,600
Reusable with 12+ months of battery life
Export options include PDF, Microsoft Excel and JPEG
Note
EasyLog CC software is freely available for use with the Lascar EL-CC-1 range of cold chain data loggers. It is compatible with Windows XP, 7, 8 & 10. It is not compatible with Mac or Linux. Link to software download https://www.lascarelectronics.com/software/easylog-cold-chain/
Supplied with
Measurement leads and wall mount clip
Related links
- Lascar EL-CC-1 Temperature Data Logger 1 Input Channel(s)
- Lascar EL-CC-1-001 Temperature Data Logger 1 Input Channel(s)
- Lascar EL-PDF-1-002 PK10 Temperature Data Logger 1 Input Channel(s)
- Lascar EL-CC-2-004 Temperature & Humidity Data Logger 1 Input Channel(s)
- Lascar EL-GFX-DTP Temperature Data Logger 1 Input Channel(s)
- Lascar EL-USB-1 Temperature Data Logger 1 Input Channel(s)
- Lascar EL-USB-TPX+ Temperature Data Logger Data Logger 1 Input Channel(s)
- Lascar EL-USB-TP-LCD Temperature Data Logger 1 Input Channel(s)