Megger MPAC128 ATEX Acoustic Imager Capacitive Touch Display Display
- RS Stock No.:
- 141-941
- Mfr. Part No.:
- 1015-885
- Manufacturer:
- Megger
Subtotal (1 unit)*
SGD55,137.12
(exc. GST)
SGD60,099.46
(inc. GST)
FREE delivery for orders over $150, or create a business account to enjoy free delivery from just $28
In Stock
- 1 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 + | SGD55,137.12 |
*price indicative
- RS Stock No.:
- 141-941
- Mfr. Part No.:
- 1015-885
- Manufacturer:
- Megger
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Megger | |
| Product Type | Acoustic Imager | |
| Battery Type | Rechargeable Lithium-ion | |
| Battery Life | 4h | |
| Display Type | Capacitive Touch Display | |
| IP Rating | IP54 | |
| Field of View FOV | 48, 62° | |
| Minimum Operating Temperature | -20°C | |
| Maximum Operating Temperature | 50°C | |
| Weight | 1.7kg | |
| Standards/Approvals | IEC 610101, IEC 6007911 II 3G Ex ic IIC T5 Gc, IEC 613261: Portable Electromagnetic Environment, IEC 600790, IEC 6132622, RoHS, Class A, CISPR 11: Group 1 | |
| Model Number | MPAC128 ATEX | |
| Select all | ||
|---|---|---|
Brand Megger | ||
Product Type Acoustic Imager | ||
Battery Type Rechargeable Lithium-ion | ||
Battery Life 4h | ||
Display Type Capacitive Touch Display | ||
IP Rating IP54 | ||
Field of View FOV 48, 62° | ||
Minimum Operating Temperature -20°C | ||
Maximum Operating Temperature 50°C | ||
Weight 1.7kg | ||
Standards/Approvals IEC 610101, IEC 6007911 II 3G Ex ic IIC T5 Gc, IEC 613261: Portable Electromagnetic Environment, IEC 600790, IEC 6132622, RoHS, Class A, CISPR 11: Group 1 | ||
Model Number MPAC128 ATEX | ||
- COO (Country of Origin):
- CN
MPAC128-ATEX Acoustic Imaging Camera
The Megger MPAC128-ATEX is a cutting-edge acoustic camera designed specifically for use in hazardous Zone 2 areas. This advanced tool empowers technicians to swiftly and accurately identify potential hazards, such as gas leaks, pressure leaks, vacuum leaks, and electrical partial discharge, in explosive atmospheres.
The Megger MPAC128-ATEX provides ATEX-certified safety without compromising performance. Identifying gas, pressure, and vacuum leaks, as well as corona, arcing, and partial discharge faults up to 120 meters away, including challenging areas, this model ensures prompt action to restore safety and system integrity in finished products, process plants, and electrical installations.
Features and Benefits:
• ATEX Certified - ensures safe operation in hazardous environments
• High-Resolution Imaging - precisely locates sound sources with a 128-microphone array
• Robust and Reliable - IP54-rated design withstands harsh conditions
• Wide Frequency Range - detect a broad spectrum of sounds, from low-frequency mechanical vibrations to high-frequency electrical discharges, with a detection frequency of up to 48 kHz
• Extended Detection Range - identify issues from up to 120 meters, making it ideal for large-scale inspections
• Crystal-Clear Visuals - the 8 MP optical camera ensures sharp and detailed visual images, providing context for the acoustic data
• Intuitive User Interface - navigate effortlessly with the 7-inch touch screen, accessing powerful tools and analytics
• Intelligent Analytics - leverage advanced algorithms to automatically identify potential issues, saving time and effort
• Real-Time Ultrasonic Monitoring - Continuously monitor critical equipment and receive alerts for anomalies, preventing costly downtime
• Safe and non-intrusive - ultrasonic detection is a safe and non-intrusive method that does not require direct contact with the equipment being inspected
Applications:
The MPAC128-ATEX is ideally suited for various industries and applications where safety and precision are paramount, especially in hazardous environments which include:
Oil and Gas - pipeline inspection and plant maintenance
Offshore platforms - Locating gas leaks in harsh and hazardous conditions
Chemical Industry - plant maintenance, process control and safety inspections
Power Generation and Transmission - electrical substation inspection, wind turbine maintenance and power plant maintenance
Manufacturing - identifying air leaks in compressed air systems
Automotive - detecting leaks in air conditioning systems and other components
Aerospace - inspecting aircraft components for potential issues
What is the difference between the MPAC128 and MPAC128-ATEX?
The primary difference between the MPAC128 and MPAC128-ATEX lies in their safety certifications and intended use in hazardous environments.
MPAC128 (RS 141-942):
• Designed for general industrial use
• Not certified for use in hazardous areas
• Ideal for detecting leaks and partial discharge in non-hazardous environments
MPAC128-ATEX (RS 141-941):
• Certified for use in hazardous Zone 2 areas (II 3G Ex ic IIC T5 Gc)
• Specifically designed for environments where explosive gases may be present
• Ideal for industries like oil refineries, chemical plants, and other hazardous locations
Related links
- Megger MPAC128 Acoustic Imager, 1024 x 600pixel Display
- Fluke ii915 Acoustic Imager, 7in Display
- FLIR Si1-LD Acoustic Imager, 5in Display
- Fluke ii905 Acoustic Imager, 7in Display
- Fluke ii500 Acoustic Imager, 7in Display
- Fluke ii910 Acoustic Imager, 7in Display
- Fluke ii900 Acoustic Imager, 7in Display
- FLIR Si2-LD Acoustic Imager, 5in Display
