+90°C 2.5 A Thermal Fuse, Limitor, 250V ac

  • RS Stock No. 176-9154
  • Mfr. Part No. P82 90 05100
  • Manufacturer Limitor
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

P82 Series

High thermal sensitivity - unnecessary to mount directly in windings
Resets when temperature falls below operating point
Body material impregnation proof and resistant to pressure, heat and most chemicals - suitable for encapsulation
De-rate breaking capacity to 1·6A for reactive loads

Note

Multi-Use / Self Resetting

Approvals

VDE, SEV, BEAB, UL, CSA

Approvals

VDE, SEV, UL Pending

PCB Wire Ended

Thermal fuses protect equipment against fire or thermal damage due to overload or overcharge. Suitable for use with standard single phase supplies up to 250V (230V typical). Temperature gradient: 1°C per minute.

Specifications
Attribute Value
Functioning Temperature +90°C
Maximum Current 2.5 A
Voltage Rating 250 V ac
Lead Orientation Radial
Body Height 8mm
Body Length 17.5mm
Body Width 4mm
Wire Diameter 0.51mm
Wire Length 100mm
Temporarily out of stock - back order for despatch 09/11/2020, delivery within 5 working days from despatch date
Price Each
SGD 9.81
(exc. GST)
SGD 10.50
(inc. GST)
units
Per unit
1 - 24
SGD9.81
25 - 99
SGD8.98
100 - 249
SGD8.27
250 - 499
SGD7.73
500 +
SGD7.44
Related Products
Neozed fuse links from Mersen limit and cut ...
Description:
Neozed fuse links from Mersen limit and cut off unacceptable over currents and short circuit currents up to their nominal breaking capacity. Constructed from an insulated body these fuses are suitable for high mechanical and thermal impacts. Typical applications for ...
Semiconductor protection fusesOperating class gR (full-range semiconductor protection)With ...
Description:
Semiconductor protection fusesOperating class gR (full-range semiconductor protection)With blade contacts, for installation in NH fuse bases or load switchesSITOR NH fuse links are designed for the overload and short circuit protection of cables, wires and power rails as well as ...
NH fuses with combination sensorsWith insulated grip tabsOperating ...
Description:
NH fuses with combination sensorsWith insulated grip tabsOperating class gG (for cable and line protection)For selective line protection and system protection in functional building, industry and power supply companies.
NH fuse links with front indicatorThe front-face red ...
Description:
NH fuse links with front indicatorThe front-face red indicator signals when the fuse cuts outOperating class gG (for cable and line protection)For selective line protection and system protection in functional building, industry and power supply companies.