Festo 230 V ac Solenoid Coil Solenoid Valve Coil
- RS Stock No.:
- 181-6468
- Distrelec Article No.:
- 301-69-036
- Mfr. Part No.:
- MSFW-230-50/60
- Manufacturer:
- Festo
Bulk discount available
Subtotal (1 unit)*
SGD42.76
(exc. GST)
SGD46.61
(inc. GST)
FREE delivery for orders over $150, or create a business account to enjoy free delivery from just $28
In Stock
- 28 unit(s) ready to ship from another location
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units | Per unit |
|---|---|
| 1 - 4 | SGD42.76 |
| 5 - 24 | SGD41.92 |
| 25 + | SGD34.49 |
*price indicative
- RS Stock No.:
- 181-6468
- Distrelec Article No.:
- 301-69-036
- Mfr. Part No.:
- MSFW-230-50/60
- Manufacturer:
- Festo
Specifications
Technical data sheets
Legislation and Compliance
Product Details
Find similar products by selecting one or more attributes.
Select all | Attribute | Value |
|---|---|---|
| Brand | Festo | |
| Supply Voltage | 230 V ac | |
| Product Type | Solenoid Coil Solenoid Valve Coil | |
| Standards/Approvals | to EU directive low-voltage devices | |
| Select all | ||
|---|---|---|
Brand Festo | ||
Supply Voltage 230 V ac | ||
Product Type Solenoid Coil Solenoid Valve Coil | ||
Standards/Approvals to EU directive low-voltage devices | ||
- COO (Country of Origin):
- DE
Festo Solenoid Coil, 230V AC, 3 Pin - MSFW-230-50/60
This solenoid coil from Festo is an essential component in electro-pneumatic systems. Consisting of a wind of wire wrapped around a metal core, this device is used to create motion. It does this by establishing an electromagnetic field around a piston that causes it to shift forward or backwards. Duroplast housing material provides reliable insulation and protection from electric shock. You'll find units like this one commonly used alongside direct-acting or pilot-operated pneumatic valves to control cylinders. You can also use it as a relay in automobile ignition systems.
• Supply voltage of 230V or heavy-duty industrial applications
• Copper winding material for high electrical conductivity
• Simple plug vane electrical connection eliminates the need for complex tools
• Can be assembled in any position for flexibility
• Low power consumption of 7VA for energy efficiency
Applications
• Automatic door-locking devices
• Medical equipment
• Robotics and automation systems
How can I tell if a solenoid coil needs to be replaced?
You can carry out a simple test using a multimeter. Set your multimeter on Ohms (resistance) and set it on 2kOhms if it's not automatic. Place the probes on the two solenoid coil pins and check the reading on the multimeter. A reading of zero means your coil is shorted and should be replaced.
Related links
- Festo Series MSFW 230 V ac Replacement Solenoid Coil Solenoid Valve Coil
- Festo Series MSF 230 V Replacement Solenoid Coil Solenoid Valve Coil
- Festo Series MSFW 230 V Solenoid Valve Coil
- Festo Series MSF 110 V ac Solenoid Coil Solenoid Valve Coil
- Festo Series MSFW 24 V Solenoid Coil Solenoid Valve Coil
- Festo Series MSFW 110 V ac Replacement Solenoid Coil Solenoid Valve Coil
- Festo 230 V ac Replacement Solenoid Coil Solenoid Valve Coil
- Festo Series MSFW 48 V ac Replacement Solenoid Coil Solenoid Valve Coil