Pilz PZE 9, 24 V dc Safety Relay, 8 Safety Contacts, 1

Subtotal (1 unit)*

SGD606.01

(exc. GST)

SGD660.55

(inc. GST)

Add to Basket
Select or type quantity
In Stock
  • 11 unit(s) ready to ship from another location
  • Plus 12 unit(s) shipping from 16 March 2026
  • Plus 8 unit(s) shipping from 30 March 2026
Need more? Click ‘Check delivery dates’ to find extra stock and lead times.
Units
Per unit
1 +SGD606.01

*price indicative

RS Stock No.:
245-1955
Distrelec Article No.:
304-10-483
Mfr. Part No.:
774150
Manufacturer:
Pilz
Find similar products by selecting one or more attributes.
Select all

Brand

Pilz

Product Type

Safety Relay

Safety Contacts

8

Contact Configuration

8 NO/1 NC

Number of Auxiliary Contacts

1

Reset Method

Automatic

Mount Type

DIN Rail

Series

PZE 9

Power Consumption

3.5W

Terminal Type

Screw

IP Rating

IP54, IP40, IP20

Standards/Approvals

EN 60068-2-6, EN 954-1, EN 60204-1, EN 60068-2-78, EN 60947-5-1, EN 60947-1, EN 61000-6-2, IEC 60204-1, EN 60947-4-1

Contact Current

8A

Switching DC Voltage

24 V dc

Minimum Operating Temperature

-10°C

Maximum Operating Temperature

55°C

Length

87mm

Width

90 mm

Height

121mm

Hazardous Area Certification

No

Safety Category

4

Coil Voltage

24 V dc

COO (Country of Origin):
FR

PZE 9 24VDC 8n/o Safety Relay Expansion from PILZ


The PILZ PZE 9, primarily used for increasing the number of contacts you can use between your safety related control devices such as E stops, safety gates and more. The reliability Safety Relay technology from PILZ means you can control your environment with confidence that the safety status is being monitored.

Features and benefits


• Universal power supply, compatible with many different outlets of power sources

• LED indicator for switching your channel status from 1 to 2 and also to monitor your supply voltage

• Plug in terminal connections with either a spring loaded terminal or screw terminal giving you versatility in where your unit can be used.

• Feedback loop monitoring come with all base units allowing you to monitor the safety loop and identify hazards before they happen.

• Single or Dual channel input operation (Single channel are used more beneficially with smaller type machines where you need to use a dedicated logic device that only has a small function to cut off in an emergency – Dual allows you to take control of more safety circuits and control a greater amount of control zones at any given time)

Safety features


• Earth fault in the feedback loop can be detected depending on the base unit that is used

• Earth faults in the input circuit can be detected as the output will de-energise the relays and open the safety contacts.

• The device will retain its safety functions in any case of component failures ensuring your safety.

• Any safety functions in your existing circuit can be easily transferred with this expansion module with ease.

• Detection of shorts across contacts is possible with this expansion model

Applications

• Guard systems
• Emergency stop buttons
• Pull wire emergency stop switches
• Safety light curtains
• Safety sensors


Technical safety parameters

• EN 60204-1

• EN 62061

• EN ISO 13849-1

• VDE 0113-1

Note

All base units must have a feedback control loop

Approvals

60204-1; EN60947-4-1; EN60947-5-1

Related links