ifm electronic Capacitive Barrel-Style Proximity Sensor, M30 x 1.5, 24 mm Detection, PNP Output, 10 → 30 V dc,
- RS Stock No.:
- 144-4448
- Mfr. Part No.:
- KI5311
- Manufacturer:
- ifm electronic
Temporarily out of stock - back order for despatch 18/06/2024, delivery within 4 working days from despatch date
Added
Price Each
SGD180.69
(exc. GST)
SGD196.95
(inc. GST)
Units | Per unit |
1 + | SGD180.69 |
- RS Stock No.:
- 144-4448
- Mfr. Part No.:
- KI5311
- Manufacturer:
- ifm electronic
Technical data sheets
Legislation and Compliance
- COO (Country of Origin):
- DE
Product Details
IFM KI5 M30 Capacitive Barrel Proximity Sensor
ifm electronic KI5 M30 capacitive sensors feature a 12-LED bar display to give visibility of sensor performance allowing the adaption of the switch point to suit the application conditions. The green LEDs either side of the switch point indicate the reliability of the switch point. Deposits and material changes are displayed directly on the sensor. An imminent error can be detected in good time and avoided, minimising the risk of failures or deactivation.
Features and Benefits
IO-Link communication
Unique visualisation and handling concept via LED display
See and compensate switch point movement
IP69K gives high ingress resistance
PNP/ NPN, NO/ NC, timer function
For medium temperatures up to 110°C
Specifications
Attribute | Value |
---|---|
Thread Size | M30 x 1.5 |
Sensor Technology | Capacitive |
Body Style | Barrel |
Output Type | PNP |
Detection Range | 24 mm |
Terminal Type | 4-Pin M12 Connector |
Supply Voltage | 10 → 30 V dc |
IP Rating | IP65, IP67, IP69K |
Communication Protocol | IO-LINK |
Length | 92mm |
Switching Frequency | 40 Hz |
Maximum DC Voltage | 30V |
Switching Current | 22 mA |
Maximum Operating Temperature | +80°C |
Housing Material | PBT, PC, POM |
Shielding | Unshielded |
Minimum Operating Temperature | -25°C |
Short Circuit Overload Protection | Yes |
Reverse Polarity Protection | Yes |
Standards Met | CE, cULus, DIN EN 60947-5-2, EAC, EN 55011, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-6, IEC 61131-9 |