Siemens Sirius Classic 3RT1 3 Pole Contactor, 3NO, 9 A, 4 kW, 230 V ac Coil

  • RS Stock No. 243-6625
  • Mfr. Part No. 3RT1016-1AP02
  • Manufacturer Siemens
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

Contactors - 3RT10 Range

The Siemens 3RT10 Range of Contactors will provide excellent reliability and are of extremely good quality.

Features and Benefits

Various NO/NC models available.
Maximum switching voltage 690V
Mechanical life 3 x 107 operations

Approvals

UL/CSA

Note

Stock 7515562 - Coils supplied separately

Standards

  • IEC947,

  • VDE0660,

  • EN60947

Note

Stock 7515562 - Coils supplied separately

Approvals

UL/CSA

Standards

IEC947, VDE0660, EN60947

Siemens Sirius Range Contactor & Control Relays

Specifications
Attribute Value
Coil Voltage 230 V ac
Number of Poles 3
Contact Current Rating 9 A
Power Rating 4 kW
Range SIRIUS Classic
Series 3RT1
Normal State Configuration 3NO
Contact Voltage Rating 400 V ac
Number Of Auxiliary Contacts 1
Terminal Type Screw
Maximum Operating Temperature +60°C
Depth 72mm
Length 57.5mm
Width 45mm
Minimum Operating Temperature -25°C
Temporarily out of stock - back order for despatch when stock is available
Price Each
SGD 67.79
(exc. GST)
SGD 72.54
(inc. GST)
units
Per unit
1 +
SGD67.79
Related Products
Eaton's range of DILEM & DILEEM contactors are ...
Description:
Eaton's range of DILEM & DILEEM contactors are predominantly used in larger-scale operations, they are designed to provide a long mechanical and electrical life which in turn accomplishes reliability. Users will commonly find these contactors integrated within industrial buildings and ...
Contactor, Size 00, 3-pole, AC-3 4 kW/400 V, ...
Description:
Contactor, Size 00, 3-pole, AC-3 4 kW/400 V, Screw terminal Auxiliary switch 01E (1 NC) 24 VDC DC operation Phased-out product Successor is SIRIUS 3RT201 or 3TG10.
Hum-free MCS installation contactor. Low-noise continuous operation due ...
Description:
Hum-free MCS installation contactor. Low-noise continuous operation due to a special magnet system with low-loss winding and iron core. The contacts can be used as both main and auxiliary contacts. All devices are furnished as standard with a switch position ...
The mechanical lock between the two contactors prevents ...
Description:
The mechanical lock between the two contactors prevents one of the contactors from switching on, as long as the other is still switched on and vice versa. Switching over reversing contactors too quickly poses the risk of a phase short ...