United Automation, PFC2 30KVR, Power Factor Switch, 50A, 3kg, 205 x 155 x 120mm

Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
Product Details

PFC2 30/50kVAR Power Factor Switches

The PFC2 controllers are suitable for 3-wire, 3-phase floating-star or closed-delta configured capacitive loads for Power Factor Correction and can be used in capacitor banks with or without chokes fitted. They are designed to dramatically reduce the inrush current normally found with contactor-based systems and could be used in situations where rapid changes in Power Factor occur such as welding plants, lifts, cranes and wind-powered plants.

Current rating: 50A (30kVAR), 75A (50kVAR) @ 415Vrms
Input voltage: 415Vrms ±10%
Frequency: 50/60Hz
Control signal input: +8 to +24Vdc, Common 0V or Common +VE, Open Collector or Volt Free Contact
Alarm relay functions: Voltage free alarm relay is rated for 125Vac @ 2A.
LED indicators: Green = DC Power ON, Red = Fault, Orange = Signal enabled, Red/Orange = Capacitors discharging
Cooling fan: +24Vdc (50KVAR model only)
Fan ’switch-on’: 50KVAR units typically +55ºC
Over Temperature: Trip in temperature: +90ºC ±1ºC (Status LED indicator ’flashes’ with ON/OFF rapid pulsing
Trip out temperature: +85ºC ±1ºC
Phase loss detection: Phase loss or Fuse failure orange and red LEDs flash alternately
Status LED Fault condition: Status LED indicator ’flashes’ ON/OFF continuously at 1.5 second intervals
Sensor loss detection: Status LED indicator ’flashes’ ON/OFF continuously in equal intervals
Power cable terminations: Supply and Load16mm² rising clamp terminal block
Earth16mm² rising clamp terminal block
Terminal torque settings: 2.5Nm (16mm²) Power terminals only
Signal cable terminations: Remote supply Auxiliary alarm (relay) 2.5mm² rising clamp terminal block
Control signal 2.5mm² rising clamp terminal block
Environmental Protection: IP20
Fusing 30kVAR: 63ET (63A) High-Speed Semiconductor type fuse, or equivalent
Fusing 50kVAR: 100ET (100A) High-Speed Semiconductor type fuse, or equivalent
Working temperature: +65°C (maximum operational)
Dimensions: 205 x 155 x 120mm
Fixing centres: 4 x 4.5mm-clear keyhole slots on fixing centres 140 x 140mm
Weight: (30kVAR) 3.0kg (50kVAR) 3.4kg

RS Product Codes
919-6220 PFC2 30kVAR
919-6239 PFC2 50kVAR

Warning

  • Metal parts, in particular the case may get very hot when the unit is fully operational.
Specifications
Attribute Value
Current Rating 50A
Weight 3kg
Mounting Type Panel Mount
Dimensions 205 x 155 x 120mm
Fixing Centres 140 x 140mm
Length 205mm
Width 155mm
Height 120mm
Maximum Operating Temperature +65 °C
Temporarily out of stock - back order for despatch 04/08/2020, delivery within 4 working days from despatch date
Price Each
SGD 789.44
(exc. GST)
SGD 844.70
(inc. GST)
units
Per unit
1 - 4
SGD789.44
5 - 9
SGD710.50
10 +
SGD648.33
Related Products
2.5KW compact (module only)Integral heat sink for maximum ...
Description:
2.5KW compact (module only)Integral heat sink for maximum power capabilitySingle Phase 230/240Vac Input Voltage0 to 10Vdc Control InputSolid State ControlLED power level indicationOver Temperature Protection with auto shutdown and resetSimple DIN Rail or panel mountingSuitable for ceiling or radiant heating, ...
QVR/RFI: Variable min to max operation,QLC/RFI: Switched variable ...
Description:
QVR/RFI: Variable min to max operation,QLC/RFI: Switched variable potentiometer. Compact, robust, phase angle power regulators with integral RFI filter networks for controlling single phase mains driven loadsSuitable for quartz lamps, transformers or conventional resistive heating elements in single, series or ...
Compact, solid state, dual voltage device for manual ...
Description:
Compact, solid state, dual voltage device for manual proportional control of resistive loads using variable bursts of energy coincidental with mains zero crossover, ensuring complete sine wave cycles are passed through to the load. High surge 26A triacLoad rating; 0.1 ...
The PRx-E thyristor stack units provide full seamless ...
Description:
The PRx-E thyristor stack units provide full seamless control of 1/3-phase resistive loads. Burst-firing control stack uses fast pulse zero-voltage switching technology to minimise flicker and RFI problemsIntegral fusing, temperature trip, automatic reset and heatsinkHoused in bespoke enclosures with easy ...