Dehn 440 V ac 8kA DR Surge Arrester, DIN Rail Mounting

  • RS Stock No. 768-1798
  • Mfr. Part No. DR M 4P 255
  • Manufacturer Dehn
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

DEHNrail Modular Surge Arresters Type 3

Type 3 surge devices
Compact DIN rail design comprising of base and plug in protection module
High discharge current performance using varistor and spark gap circuit
Energy coordination with other Dehn Redline products in accordance with BS7671 amendment 1
Status indication using Thermo Dynamic Control for monitoring of the SPD
Tool less replacement of the plugs for repair and test functions

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage surges are usually caused by lightning and can reach up to 6000V, with current surges of over 3000A. The maximum size of the voltage and current surges depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.

Specifications
Attribute Value
Suppressor Type Surge Arrester
Maximum Voltage Rating 440 V ac
Mounting Type DIN Rail
Maximum Surge Current 8kA
Series DR
Length 90mm
Depth 36mm
Height 66mm
Dimensions 90 x 36 x 66mm
Minimum Operating Temperature -40°C
Maximum Operating Temperature +80°C
Temporarily out of stock - back order for despatch 04/03/2020, delivery within 3 working days from despatch date
Price Each
SGD 293.10
(exc. GST)
SGD 313.62
(inc. GST)
units
Per unit
1 - 4
SGD293.10
5 +
SGD278.44
Related Products
POP CT is the series of combined power ...
Description:
POP CT is the series of combined power frequency overvoltage protection (POP) and surge protection device for discharging surge current in the first step of protection. Intended for actuation on the contactor of an installation (not included). Suitable for the ...
Surge protection designed to cope with high magnitude ...
Description:
Surge protection designed to cope with high magnitude 10 / 350μs current waveforms as described in IEC 61312. IEC Class II surge protectionRemote contacts available.
Modular slim-line transient voltage suppressors designed to snap-fit ...
Description:
Modular slim-line transient voltage suppressors designed to snap-fit directly onto top hat profile DIN rails. Dual high-energy electrically isolated metal oxide varistorsFuse protection from line surges.
Type 1 and 2 prewired spark gap based ...
Description: