samos PRO SP CANOpen Communication Module, 24 V dc

  • RS Stock No. 871-4612
  • Mfr. Part No. R1.190.0210.0
  • Manufacturer Wieland
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): DE
Product Details

Wieland Samos PRO COMPACT Safety Control

The samosPRO Compact is suitable for monitoring non-contact safety sensors, emergency off buttons, protective door switches and door closures, two-hand controls as well as testable safety light barriers, light curtains and laser scanners. Not only is it suitable for use in machinery and plant engineering but also, for example, for safety-related control tasks in elevator installations, industrial combustion plants and process technology systems.

24 safe in- and outputs on 45 mm construction width for space and cost savings
USB and Ethernet interfaces for remote maintenance always on board
Industrial Ethernet protocols integrated
512 kb program memory offers space for each project
4 A switching power at each output
Ambient temperature -25 to +65 °C
Modular extendability to up to 172 secure in-/outputs
Optical display of all in- and outputs in system
Pluggable connection technology with either screw or push-in terminal blocks

SP-COP1 COMPACT Module

SILCL 3 (EN 62061-1)
PL e / Category 4 (EN ISO 13849-1)
20 safe inputs, 4 safe outputs
USB interface
SD slot for program memory (memory card ordered separately, stock no. 871-4615)

SP-COP2 COMPACT Module with Ethernet

SILCL 3 (EN 62061-1)
PL e / Category 4 (EN ISO 13849-1)
16 inputs, 4 outputs, 4 configurable I/O
USB interface
Ethernet interface
Industrial Ethernet protocol (stock no. 871-4609 only)
SD slot for program memory (memory card ordered separately, stock no. 871-4615

SP-PROFIBUS-DP Gateway

Fieldbus protocol PROFIBUS-DP
Bidirectional communication with PLC
Transfer rate 12 MBaud
Transfer of at least 50 bytes of data
Simple configuration with samos® plan

SP-CANopen Gateway

Fieldbus protocol CANopen
Bidirectional communication with PLC
Transfer rate up to 1 MBit/s
Transfer of at least 50 bytes of data
Simple configuration with samos® plan

SP-SDIO Input / Output Module

SILCL 3 (EN 62061-1)
PL e / Category 4 (EN ISO 13849-1)
8 safe inputs
4 safe outputs (with/without output test-pulses)
2 outputs (e.g. test signals)

Specifications
Attribute Value
Range Samos PRO
Series SP
Type Communication Module
For Use With SP-COP
Supply Voltage 24 V dc
Field Bus Communication Type CANopen
Connection Type Fieldbus
Display Included No
Mounting Style DIN Rail
Dimensions 22.5 x 96.5 x 121 mm
Temporarily out of stock - back order for despatch 24/11/2020, delivery within 4 working days from despatch date
Price Each
SGD 450.48
(exc. GST)
SGD 482.01
(inc. GST)
units
Per unit
1 +
SGD450.48
Related Products
The Schneider Electric TeSys island SIL interface module ...
Description:
The Schneider Electric TeSys island SIL interface module which is safe stop operable for safety related system. It has voltage rating of 24V DC and current consumption 10mA. Overvoltage category IIIIP degree of protection IP20Pollution degree 2Protective treatment TC.
The PNOZ ml1p module is used for the ...
Description:
The PNOZ ml1p module is used for the safe connection of two PNOZmulti safety systems. Can be configured in the PNOZmulti ConfiguratorPoint-to-point connection via 4-core shielded twisted-pair cable32 virtual inputs and 32 virtual outputsStatus indicatorsPlug-in connection terminalsMaximum of 4 PNOZ ...
The Omron G9SA series safety relay module has ...
Description:
The Omron G9SA series safety relay module has 3PST-NO/1SPST-NC contacts normal state configuration. It offers a line-up of compact and expandable safety relay units. The modules with safe off-delay timing are available, as well as a 2-hand controller. Simple multiplication ...
Input expander / PFB. For parallel IO devicesPassive ...
Description:
Input expander / PFB. For parallel IO devicesPassive field box for series-wiringFor devices with M12 Connector, 8-poleFor up to 4 safety switchgearsFuse protected device portsHeavy duty version for field installationProtection class IP67.