Schneider Electric 2 Pole Residual Current Circuit Breaker, 40A iID, 30mA

Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): ES
Product Details

RCCB Acti9 iID

The Acti 9 iID DIN rail RCCBs, are fully coordinated with the iC60 MCBs to warranty an absolute people and equipment protection against electrocution, risk of fire and improved continuity of service.

iID residual current circuit breakers AC Type provide:

Protection of persons against electric shock by direct contact (≦ 30 mA).
Protection of persons against electric shock by indirect contact (≧ 100 mA).
Protection of installations against the risk of fire (300 mA or 500 mA).

iID residual current circuit breakers Asi Type provide:

Protection of persons against electric shock by direct contact (≦ 30 mA).
Protection of persons against electric shock by indirect contact (≧ 300 mA).
Protection of installations against the risk of fire (300 mA or 500 mA).
Increased immunity from electrical interference and polluted or corrosive environments.

Specifications
Attribute Value
Current Rating 40A
Number of Poles 2
Trip Sensitivity 30mA
Series iID
Rated AC Voltage 240V
Mounting Style DIN Rail Mount
9 In stock for delivery within 3 working days
Price Each
SGD 225.57
(exc. GST)
SGD 241.36
(inc. GST)
units
Per unit
1 +
SGD225.57
Related Products
ID'clic differential plug-in switches, protected against inadvertent tripping. ...
Description:
ID'clic differential plug-in switches, protected against inadvertent tripping. Used only with Distri'clic XE splitters;Used for protection of "blue tariff" installations. Supply voltage 230 Vac.Standard AC graphs, A for detecting default current with continuous components or Asi for improved immunity.
Assembly comprising a two-pole differential switch and a ...
Description:
Assembly comprising a two-pole differential switch and a reset for start-up control and protection.The integrated reset automatically resets the differential switch, but only after checking the insulation of the downstream circuit.This device can be deactivated when people are present in ...
Range of plug-in circuit breakers for assembly on ...
Description:
Range of plug-in circuit breakers for assembly on Distri'clic XE splitters.Control and protection of single-phase circuits downstream of the connecting circuit breaker, for "blue tariff".Standard C graph.The magnetic circuit breakers work between 5 and 10In.Supply voltage 230Vac.Breaking capacity 3kA according ...
All-current-sensitive FI circuit breaker for detection of residual ...
Description:
All-current-sensitive FI circuit breaker for detection of residual AC currents, pulsating and smooth residual DC currentsIncreased operating reliability in networks with capacitive impedances based on adapted actuation characteristicSwitch handle and test button may be locked via handle lockTime-delayed disconnect ...