ABB 4 Pole Type AC Residual Current Circuit Breaker, 25A FH200, 30mA

  • RS Stock No. 540-1644
  • Mfr. Part No. 2CSF204006R1250
  • Manufacturer ABB
Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): DE
Product Details

2 & 4 Pole RCCB - FH200 Series

Compact AC DIN rail mount 2 and 4 Pole RCCB’s
Protects against the effects of sinusoidal alternating earth fault currents
Protects against indirect contact with additional protection against direct (with IΔn=30 mA) contact
Command and isolation of resistive and inductive circuits
Suitable for residential and commercial applications

Note

RCCBs are sensitive only to earth fault current (therefore they have to be connected in series with a MCB or a fuse to protect them against over-current and short-circuits).

Standards

IEC/EN 61008

ABB RCBO's & RCCB's

RCBO's : DIN rail mounting with an operating temperature range of -25 to +55 °C. Optimum frequency range of 50 to 60Hz

Specifications
Attribute Value
Current Rating 25A
Number of Poles 4
Trip Sensitivity 30mA
Tripping Characteristics Type AC
Series FH200
16 In stock for delivery within 4 working days
Price Each
SGD 142.78
(exc. GST)
SGD 152.77
(inc. GST)
units
Per unit
1 - 5
SGD142.78
6 - 11
SGD138.59
12 +
SGD137.06
Related Products
For use as spares and replacements in F&G ...
Description:
For use as spares and replacements in F&G Concept 2000 consumer units. Manufactured to BS EN 61009Flying lead neutral cable for easy installationType B MCB and 30mA RCD combined in one device10kA MCB/RCBO breaking capacityType B MCB/RCBO operating characteristic.
The RCCBs F200 series assures protection to people ...
Description:
The RCCBs F200 series assures protection to people and installations against fault current to earth. A large offer for standard instantaneous and selective AC and A types is completed with some configurations for special applications. This product is suitable for ...
All-current-sensitive FI circuit breaker for detection of residual ...
Description:
All-current-sensitive FI circuit breaker for detection of residual AC currents, pulsating and smooth residual DC currentsIncreased operating reliability in networks with capacitive impedances based on adapted actuation characteristicSwitch handle and test button may be locked via handle lockTime-delayed disconnect ...
Acti9 iTG40 RCCBs limits wear and reduces voltage ...
Description:
Acti9 iTG40 RCCBs limits wear and reduces voltage drops, helping to prevent premature equipment aging and overheating. VisiTrip indicates only the faulty outgoer, allowing fast diagnosis, resolution, and re-closing loads for easier building management and reduced downtimeInsulation Voltage: 440 VacVoltage: ...