ABB 4 Pole Type B Residual Current Circuit Breaker, 40A F200, 300mA

  • RS Stock No. 176-9617
  • Mfr. Part No. F204B-40/0.3
  • Manufacturer ABB
Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): IT
Product Details

ABB Residual Current Circuit Breaker

The ABB F200 series residual current circuit breaker is a 4-pole type B device. It has an electrical rating of 400V and 40A. The operation of the residual circuit breaker is indicated using a green LED. This circuit can operate in extremely harsh weather conditions up to 60°C.

Features and Benefits

• Breaking maximum voltage rating is 10KA
• Compact design
• DIN rail type mounting
• Earth fault safety protection
• Operation temperature ranges in between -25°C and 55°C
• Trip sensitivity is 300mA

Applications

• Faulty electronic circuits
• Industrial application

Certifications

• EN 62423
• IMQ
• VDE

Specifications
Attribute Value
Current Rating 40A
Number of Poles 4
Trip Sensitivity 300mA
Tripping Characteristics Type B
Voltage Rating 400V
Series F200
Overall Length 70mm
Terminal Contact Type Screw
Mounting Style DIN Rail Mount
Reset Actuator Type Toggle Switch
Earth Leakage Protection Type F
Break Time Time Delay
Circuit Breaker Type RCCB
Breaking Capacity at Maximum Voltage Rating 10 kA
Overall Depth 85mm
Overall Width 69mm
Overall Dimensions 70 x 69 x 85mm
Special Features Earth Fault Safety Protection
2 In stock for delivery within 4 working days
Price Each
SGD 1,442.55
(exc. GST)
SGD 1,543.53
(inc. GST)
units
Per unit
1 +
SGD1,442.55
Related Products
For use as spares and replacements in F&G ...
Description:
For use as spares and replacements in F&G Concept 2000 consumer units. Manufactured to BS EN 61009Flying lead neutral cable for easy installationType B MCB and 30mA RCD combined in one device10kA MCB/RCBO breaking capacityType B MCB/RCBO operating characteristic.
Assembly comprising a two-pole differential switch and a ...
Description:
Assembly comprising a two-pole differential switch and a reset for start-up control and protection.The integrated reset automatically resets the differential switch, but only after checking the insulation of the downstream circuit.This device can be deactivated when people are present in ...
The RCCBs F200 series assures protection to people ...
Description:
The RCCBs F200 series assures protection to people and installations against fault current to earth. A large offer for standard instantaneous and selective AC and A types is completed with some configurations for special applications. This product is suitable for ...
Acti9 iTG40 RCCBs limits wear and reduces voltage ...
Description:
Acti9 iTG40 RCCBs limits wear and reduces voltage drops, helping to prevent premature equipment aging and overheating. VisiTrip indicates only the faulty outgoer, allowing fast diagnosis, resolution, and re-closing loads for easier building management and reduced downtimeInsulation Voltage: 440 VacVoltage: ...