Telemecanique Sensors Air, Fresh Water, Sea Water Differential Pressure Switch, 3NC 1 → 6 (Rising)bar

Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
COO (Country of Origin): CZ
Product Details

OsiSense XMP Adjustable Differential Pressure Sensors

Osisense XMP pressure sensors are for control circuits and are used to control the pressure of water (sea and fresh) and air. XMP series pressure sensors have an adjustable differential and are for regulation between two thresholds.

Diaphragm pressure actuator
G 1/4 (female) fluid connection type
2 cable entries tapped for Pg 13.5 cable gland
2 NC snap action

Specifications
Attribute Value
Pressure Range 1 → 6 (Rising)bar
Pressure Reading Type Differential
Media Measured Air, Fresh Water, Sea Water
Output Type 3NC
Minimum Pressure Reading 1 (Rising)bar
Maximum Pressure Reading 6 (Rising)bar
Process Connection G1/2
Electrical Connection Screw Clamp
Minimum Operating Temperature -25°C
Maximum Operating Temperature +70°C
Accuracy <3.5 (Repeat) %
Mounting Type Cable Mount
IP Rating IP65
Housing Material PA Impregnated with Fibreglass
Temporarily out of stock - back order for despatch 08/11/2019, delivery within 3 working days from despatch date
Price Each
SGD 66.99
(exc. GST)
SGD 71.68
(inc. GST)
units
Per unit
1 +
SGD66.99
Related Products
Schneider Electric XMLA pressure switches for control circuits ...
Description:
Schneider Electric XMLA pressure switches for control circuits are used to control the pressure of hydraulic oils, fresh water, sea water, air, steam, corrosive fluids, or viscous products. The XMLA pressure and vacuum switches have a fixed differential and are ...
Osisense XMP pressure sensors are for control circuits ...
Description:
Osisense XMP pressure sensors are for control circuits and are used to control the pressure of water (sea and fresh) and air. XMP series pressure sensors have an adjustable differential and are for regulation between two thresholds. Diaphragm pressure actuatorG ...
Schneider Electric XMLA pressure switches for control circuits ...
Description:
Schneider Electric XMLA pressure switches for control circuits are used to control the pressure of hydraulic oils, fresh water, sea water, air, steam, corrosive fluids, or viscous products. The XMLA pressure and vacuum switches have a fixed differential and are ...
Osisense XML pressure switches are for control circuits ...
Description:
Osisense XML pressure switches are for control circuits and are used to control the pressure of hydraulic oils, fresh water, sea water, air, steam and corrosive fluids. XMLC series pressure sensors have an adjustable differential and are for regulation between ...