Fluke 2584888 Current Probe & Clamp

  • RS Stock No. 645-3668
  • Mfr. Part No. I3000S FLEX-24
  • Manufacturer Fluke
Technical data sheets
Legislation and Compliance
RoHS Status: Not Applicable
COO (Country of Origin): CN
Product Details

i3000s Flex 24 Flexible 3000A a.c. Current Probe

Suitable for use with oscilloscopes, recorders and data loggers
a.c. coupled output (no d.c. offset)
Voltage output of 3V full scale for each range
Fits around conductors up to 160mm diameter
Extended battery life and external power supply input
Meets BS EN61010 – 1 Cat III 600V
Extended working temperature range -20°C to +90°C
Conforms to EN61010-1 CAT III 600V

Supplied with

2 x AA alkaline batteries, BNC to 4mm plug adaptor and operator's manual.

Specifications
Attribute Value
Current 3000A
Probe Type AC
Minimum Bandwidth 10Hz
Maximum Bandwidth 50kHz
Maximum Conductor Size 178mm
Safety Category CAT III 600 V
Safety Category Level CAT III
Model Number p I3000S
Best Accuracy ±1 %
Safety Category Voltage 600V
Bandwidth 10 Hz → 50 kHz
7 In stock for delivery within 3 working days
Price Each
SGD 998.00
(exc. GST)
SGD 1,067.86
(inc. GST)
units
Per unit
1 +
SGD998.00
Related Products
Standard AC current pliers Inspired by the principle ...
Description:
Standard AC current pliers Inspired by the principle of the Rogowski coil.Can measure intensity up to 3000 A when used with oscilloscopes and recorders.Its flexible measurement head is light and can be easily and quickly installed into hard-to-reach places.Three ranges: ...
Dual range a.c. current clamp nominal measuring ranges ...
Description:
Dual range a.c. current clamp nominal measuring ranges 0.1A to 20A a.c. and 0.5A to 200A a.c.Safe, non intrusive current measurement40Hz to 10kHz bandwidthErgonomic jaw design for measurement where access is difficult and allows 'hooking' onto the cableMax. conductor size ...
Superior measurement range from 100mA to 3000 Aac2000 ...
Description:
Superior measurement range from 100mA to 3000 Aac2000 Hours continuous battery life (two AA MN1500 LR6 alkaline batteries, not supplied)Low battery and range overload indicationRange selection by robust rotary switchHigh external field rejectionExcellent accuracy over full rangeSmall diameter (10mm) Rogowski ...
The Tektronix TCP300 Series of split-core current probes ...
Description:
The Tektronix TCP300 Series of split-core current probes incorporates transformer and Hall effect technology. The TCP300 models TCP303 (796-2683 ), TCP305A ( 781-0810 ) and TCP312A ( 781-0801 ) are used with amplifier TCPA300 ( 764-4391 ), available separately, to ...