ADAS1000BSTZ, Analogue Front End IC, 5-Channel 19 bit, 2Msps DSP, QSPI, SPI, 64-Pin LQFP

Technical data sheets
Legislation and Compliance
RoHS Certificate of Compliance
Product Details

ADAS1000/1000-1/1000-2, Electrocardiogram (ECG) Data Acquisition Systems, Analog Devices

The ADAS1000, ADAS1000-1 and ADAS1000-2 from Analog Devices are low power, 5 electrode, electrocardiogram (ECG) analogue front ends. They measure electro cardiac (ECG) signals, thoracic impedance, pacing artefacts and lead-on/off status.

These devices are designed to simplify the task of acquiring and ensuring quality ECG signals. They provide a low power, small data acquisition system for biopotential applications.

Features

Biopotential signal input; digitized signal output
5 acquisition (ECG) channels and one driven lead
AC and DC lead-off detection
Internal pace detection algorithm on 3 leads
Selectable reference lead
Scalable noise vs. power control, power down modes
Low power operation – 11mW (1 lead) to 21mW (all electrodes)
Lead or electrode data available
Fast overload recovery
Low or high speed data output rates
Supports AAMI EC11:1991/(R)2001/(R)2007, AAMI EC38 R2007, EC13:2002/(R)2007, IEC60601-1 ed. 3.0 b:2005, IEC60601-2-25 ed. 2.0 :2011, IEC60601-2-27 ed. 2.0 b:2005, IEC60601-2-51 ed. 1.0 b: 2005

Typical applications

Bedside patient monitoring
Portable telemetry
Holter monitor
Automated external defibrillator (AED)
Cardiac defibrillators
Ambulatory monitors
Pace maker programmer
Stress testing

Specifications
Attribute Value
Number of ADCs 6
Resolution 19 bit
Sampling Rate 2Msps
Interface Type DSP, QSPI, SPI
Number of Channels per Chip 5
Mounting Type Surface Mount
Package Type LQFP
Pin Count 64
Power Supply Type Single
Dimensions 10.2 x 10.2 x 1.45mm
Height 1.45mm
Length 10.2mm
Maximum Operating Supply Voltage 1.89 V, 5.5 V
Minimum Operating Supply Voltage 1.71 V, 3.15 V
Minimum Operating Temperature -40 °C
Maximum Operating Temperature +85 °C
Width 10.2mm
1 In stock for delivery within 3 working days
Price Each
SGD 42.74
(exc. GST)
SGD 45.73
(inc. GST)
units
Per unit
1 - 9
SGD42.74
10 - 49
SGD41.89
50 - 99
SGD41.07
100 - 249
SGD40.26
250 +
SGD39.47
Packaging Options:
Related Products
Heart-Rate Monitoring (HRM) and saturation of peripheral capillary ...
Description:
Heart-Rate Monitoring (HRM) and saturation of peripheral capillary Oxygen (SpO2)Simultaneous Support of 3 LEDs24-Bit Representation of the Current Input from a PhotodiodePulse Frequency 10 SPS to 1000 SPSI²C-Bus interface.
The Texas Instruments AFE4403 analogue front-end (AFE) is ...
Description:
The Texas Instruments AFE4403 analogue front-end (AFE) is designed specifically for heart rate monitoring and pulse oximetering. It is composed of a low noise receiver channel, ADC, oscillator and dual LED driver with integrated fault detection. Connect an external microcontroller ...
The ADuCM360 is a 3.9kSPS, 24-bit data acquisition ...
Description:
The ADuCM360 is a 3.9kSPS, 24-bit data acquisition system that incorporates dual multichannel sigma-delta (Σ-Δ) analogue-to-digital converters (ADCs), an ARM Cortex-M3 core processor and memory on a single chip. The ADuCM361 has a single ADC. 2 x 24-bit multichannel Σ-Δ ...
The MCP3913 device is a 3V six-channel Analog ...
Description:
The MCP3913 device is a 3V six-channel Analog Front End (AFE, containing six synchronous sampling delta-sigma ADCs, six PGAs, phase delay compensation block, low-drift internal voltage reference, digital offset and gain error calibration registers, and high-speed 20 MHz SPI compatible ...