Magnetic Pickups

pMagnetic pickups are sensors that detect the speed of a moving part, typically in an engine. When objects like gears or shafts with keyways are passed through the sensor's magnetic field, the field oscillates, which induces  in the sensor's coil an AC voltage to be read by an electrical device such as a counter or oscilloscope./p pbr/p pstrongFeatures of a magnetic pickup/strong/p pA magnetic pickup is a coil that is wound around a magnetised probe. When objects like gear teeth, turbine rotor blades, slotted discs or shafts pass through the probe's magnetic field, the flux density is modulated, inducing a measurable AC voltage. Magnetic pickups tend to have a high-output voltage that is suitable for use with heavy-duty wiring. They are generally unaffected by dust and dirt, and are sturdier than most other plastic sensors. /p pbr/p pstrongWhat can magnetic pickups be used for?/strong/p pMagnetic pickups can be used as parts of speedometers or a href="https://uk.rs-online.com/web/c/test-measurement/rotational-measurement/tachometers/?redirect-relevancy-data=636F3D3126696E3D4931384E53656172636847656E65726963266C753D656E266D6D3D6D61746368616C6C7061727469616C26706D3D5E2E2A2426706F3D31333326736E3D592673723D52656469726563742673743D43415443485F414C4C5F44454641554C542673633D592677633D4E4F4E45267573743D746163686F6D65746572267374613D746163686F6D6574657226&r=f&sra=oss" title="https://uk.rs-online.com/web/c/test-measurement/rotational-measurement/tachometers/?redirect-relevancy-data=636F3D3126696E3D4931384E53656172636847656E65726963266C753D656E266D6D3D6D61746368616C6C7061727469616C26706D3D5E2E2A2426706F3D31333326736E3D592673723D52656469726563742673743D43415443485F414C4C5F44454641554C542673633D592677633D4E4F4E45267573743D746163686F6D65746572267374613D746163686F6D6574657226&r=f&sra=oss"tachometers,/a which are integral parts of engines and industrial equipment./p

...
Read more Read less

Filters

Viewing 1 - 20 of 38 products
Results per page
Description Price Body Style Output Type Detection Range Switching Frequency Reverse Polarity Protection Short Circuit Overload Protection Terminal Type Mounting Style Switching Current Maximum AC Voltage Maximum DC Voltage Thread Size Supply Voltage Housing Material
RS Stock No. 304-166
BrandRS PRO
SGD20.94
Each
units
Barrel Analogue 2.5 mm - - - Wire Lead - - - - 1/4-28 UNF-2A 10 V Stainless Steel
RS Stock No. 285-762
BrandRS PRO
SGD121.23
Each
units
Barrel PNP 2.5 mm - - - Connector - - - - 5/8-18 UNF-2A 190 V Stainless Steel
RS Stock No. 304-172
BrandRS PRO
SGD74.76
Each
units
Barrel Digital 2.5 mm - - - Wire Lead - - - - 1/4-40 UNS-2A 5 → 15 V dc Stainless Steel
RS Stock No. 285-756
BrandRS PRO
SGD64.81
Each
units
Barrel PNP 2.5 mm - - - Wire Lead - - - - 3/8-24 UNF-2A 60 V Stainless Steel
RS Stock No. 313-2295
Mfr. Part No.BIM-IKT-Y1X
BrandTurck
SGD56.25
Each
units
- NO - ≤1 kHz - - Cable Bracket, Tie Rod 100 mA - - - 8.2 V dc Gadolinium Zinc
RS Stock No. 307-6195
Mfr. Part No.PSA60010
BrandCelduc
SGD33.24
Each
units
Block - 12 mm - - - Wire Lead - 3 A 440V - - - -
RS Stock No. 313-2374
Mfr. Part No.BIM-UNT-AP6X-0.3-PSG3M
BrandTurck
SGD121.52
Each
units
Block PNP - - Yes Yes 3-Pin M8 Connector Bracket 200 mA - 30V - 10 → 30 V dc Polyamide, Stainless Steel
RS Stock No. 814-1055
Mfr. Part No.BMF 235K-PS-C-2A-SA2-S49-00,3
BrandBALLUFF
SGD51.99
Each
units
Barrel PNP - 3 kHz Yes Yes Cable Cable - - 30V - 10 → 30 V dc Polyamide
RS Stock No. 814-1171
Mfr. Part No.BMF 214K-PS-C-2A-SA2-S49-00,3
BrandBALLUFF
SGD46.38
Each
units
Barrel PNP - 7 kHz Yes Yes Cable Cable - - 30V - 10 → 30 V dc Polyamide
RS Stock No. 173-2634
Mfr. Part No.AA747AHA-LB
BrandSensitec
SGD2.353
Each (On a Reel of 4000)
units
Block Analogue - - - - - Surface Mount - 9V - - ±9 V -
RS Stock No. 123-6288
Mfr. Part No.AFF755BHA-AD
BrandSensitec
SGD3.078
Each (On a Reel of 4000)
units
- - - - - - - - - - - - - -
RS Stock No. 786-5829
Mfr. Part No.MPS-160TSTP0
BrandSick
SGD587.00
Each
units
Barrel Analogue 160 mm - Yes Yes 4-Pin M8 Connector Drop In 20 mA - 30V - 15 → 30 V dc Plastic
RS Stock No. 814-1187
Mfr. Part No.BMF 204K-PS-C-2A-SA2-S49-00,3
BrandBALLUFF
SGD45.04
Each
units
Barrel PNP - 7 kHz Yes Yes Cable Cable - - 30V - 10 → 30 V dc Polyamide
RS Stock No. 765-9595
Mfr. Part No.AFF755BHA-AD
BrandSensitec
SGD5.39
Each
units
Block Analogue - 1 MHz - - - Surface Mount ±1 A 9V - - 1.2 → 9 V -
RS Stock No. 905-5298
Mfr. Part No.MP37TA00
BrandRed Lion
SGD51.85
Each
units
Barrel NO - - - - M12 Connector Threaded - - - M12 1 V Steel
RS Stock No. 517-2807
Mfr. Part No.MHRM 12G2501
BrandBaumer
SGD408.07
Each
units
- PNP 0.5 (Module 1) mm, 1 (Module 2) mm 0 → 15 kHz Yes Yes Wire Lead - - - - M12 8 → 28 V dc Stainless Steel
RS Stock No. 765-9592
Mfr. Part No.AA747AHA-LB
BrandSensitec
SGD1.96
Each
units
Block Analogue - - - - - Surface Mount - 9V - - ±9 V -
RS Stock No. 741-7534
Mfr. Part No.MR0100
SGD34.61
Each
units
Block PNP/NPN - 1 kHz Yes - Cable Flush 100 mA 120V 120V - 5 → 120 V ac/dc Polyamide
RS Stock No. 905-5292
Mfr. Part No.MP62TA00
BrandRed Lion
SGD59.56
Each
units
Barrel NO - - - - M12 Connector Threaded - - - 5/8-18 UNF-2A 1 V Steel
RS Stock No. 111-3708
Mfr. Part No.MZT7-03VPS-KW0
BrandSick
SGD47.00
Each
units
Block PNP-NO 10 mm 1 kHz Yes Yes Wire Lead Panel 100 mA - 30V - 10 → 30 V dc Plastic
Related Products
The Phoenix Contact CMS P1 Plotter can be ...
Description:
The Phoenix Contact CMS P1 Plotter can be used to label sheet materials, UniCard and label strips. The integrated pen station facilitates handling and helps to prevent the pens from drying out. The CMS P1 Plotter can also be converted ...
Magnetic cylinder sensors are used for detection, measuring ...
Description:
Magnetic cylinder sensors are used for detection, measuring and positioning in many crucial tasks. PA12 plastic body materialSuitable for T-slot and round-slot cylindersPNP NO or reed switchPNP output types have short circuit and reverse polarity protectionLED status display.
Sensor for pneumatic cylindersRecords the ring magnets in ...
Description:
Sensor for pneumatic cylindersRecords the ring magnets in the cylinder pistonsPrecise recording of position by means of accurate switching pointsOutput: N/OOutput current max. 100 mAResponse threshold 2.1 mTTraverse speed > 10 m/sPolarity reversal protectionLED status displayConnection lead with plug ...
Magnetic cylinder sensors are used for detection, measuring ...
Description:
Magnetic cylinder sensors are used for detection, measuring and positioning in many crucial tasks. PA12 plastic body materialSuitable for T-slot and round-slot cylindersPNP NO or reed switchPNP output types have short circuit and reverse polarity protectionLED status display.