Current Transducers

Current transducers, or current sensors, are an electrical component that detects electric current in a wire and converts it into another type of electrical signal proportional to the current value. The generated signal could be analogue voltage, current or a digital output. This generated signal can be then used to display the measured current in an ammeter, or can be used for the purpose of controlling other circuits.

Current Transducer Types

Current sensors can be either open-loop or closed-loop.
•Open-Loop Sensor: This type measures AC and DC currents and provides electrical isolation between the circuit being measured and the output of the sensor. Open-loop current sensors are generally preferred in battery-powered circuits.


•Closed-Loop Sensor: The Closed-Loop sensor is sometimes called a ’Zero-Flux’ sensor because it features a Hall-Effect sensor that feeds back an opposing current into a secondary coil, wound on the magnetic core to zero the flux produced in the magnetic core by the primary current. Closed-loop sensors are often used when high accuracy is essential.

...
Read more Read less

Filters

Viewing 1 - 20 of 358 products
Results per page
Description Price Input Current Range Sensor Technology Nominal Current Output Current Range Supply Voltage Transformer Type Maximum Cable Diameter Sensor Type Mounting Type Frequency Bandwidth Accuracy Bore Size Minimum Operating Temperature Series
RS Stock No. 522-030
Mfr. Part No.AT 5 B420L
BrandLEM
SGD109.98
Each
units
- - 5A 4 → 20mA 20 → 30 V dc - - - Cable Tie 50/60 Hz ±1.5 % 16mm -20°C AT
RS Stock No. 286-361
Mfr. Part No.LV 25-P
BrandLEM
SGD105.80
Each
units
- Closed Loop 0 → 14 25mA 12 → 15 V - - Hall Effect PCB Mount - ±0.9 % - 0°C LV
RS Stock No. 521-992
Mfr. Part No.LF 205-S/SP3
BrandLEM
SGD86.72
Each
units
- Closed Loop 0 → 200A 100mArms 12 → 15 V - - Hall Effect Panel Mount DC to 100 kHz ±0.5 % 15.5mm -40°C LF
RS Stock No. 198-807
Mfr. Part No.AT 10 B10
BrandLEM
SGD82.18
Each
units
- - 10A - - - - - Cable Tie 50/60 Hz ±1.5 % 16mm -20°C AT
RS Stock No. 189-5477
Mfr. Part No.CSNE151
BrandHoneywell
SGD52.58
Each
units
- Closed Loop 5 → 36A 25mA 15 V - - Hall Effect PCB Mount DC to 150 kHz ±0.5 % - 0°C CSN
RS Stock No. 497-378
Mfr. Part No.AT 50 B10
BrandLEM
SGD126.31
Each
units
- - 50A - - - - - Cable Tie 50/60 Hz ±1.5 % 16mm -20°C AT
RS Stock No. 286-311
Mfr. Part No.LA 25-NP
BrandLEM
SGD38.51
Each
units
- Closed Loop 0 → 36A 25mArms 15 V - - Hall Effect PCB Mount DC to 150 kHz ±0.5 % - -40°C LA
RS Stock No. 180-7357
Mfr. Part No.LA 55-P
BrandLEM
SGD37.49
Each
units
- Closed Loop 0 → 70A 50mArms 12 → 15 V - - Hall Effect PCB Mount DC to 200 kHz ±0.9 % - -40°C LA
RS Stock No. 451-1324
Mfr. Part No.LA 100P/SP13
BrandLEM
SGD37.56
Each
units
- Closed Loop 0 → 160A 100mArms 12 → 15 V - - Hall Effect PCB Mount DC to 200 kHz ±0.7 % 12.7 x 7mm -25°C LA
RS Stock No. 497-221
Mfr. Part No.LA 25-P
BrandLEM
SGD58.71
Each
units
- Closed Loop 0 → 55A 25mArms 12 → 15 V - - Hall Effect PCB Mount DC to 200 kHz ±1.25 % - -25°C LA
RS Stock No. 198-841
Mfr. Part No.AT 5 B5
BrandLEM
SGD93.25
Each
units
- - 5A - - - - - Cable Tie 50/60 Hz ±1.5 % 16mm -20°C AT
RS Stock No. 302-6077
Mfr. Part No.2814359
SGD409.17
Each
units
- - 0 → 5A 0 → 20mA - - - - Chassis Mount 45 → 60 Hz <0.5 % - -25°C MCR-SLP-1-5-UI-0
RS Stock No. 198-835
Mfr. Part No.AT 20 B10
BrandLEM
SGD95.11
Each
units
- - 20A - - - - - Cable Tie 50/60 Hz ±1.5 % 16mm -20°C AT
RS Stock No. 715-7989
Mfr. Part No.2308030
SGD429.26
Each
units
- - 0 → 200A 4 → 20mA 20 → 30 V dc - - - DIN Rail 20 → 6000 Hz ±1 % 32mm -40°C MCR-SL-CUC-200-I
RS Stock No. 207-2984
Mfr. Part No.LA 205-S
BrandLEM
SGD146.44
Each
units
- Closed Loop 0 → 300A 100mArms 12 → 15 V - - Hall Effect Panel Mount DC to 100 kHz ±0.8 % 22.7 x 17.4mm -10°C LA
RS Stock No. 181-2129
Mfr. Part No.CSLA2CD
BrandHoneywell
SGD31.65
Each
units
- Open Loop 0 → 72A - 6 → 12 V dc - - Hall Effect PCB Mount - - 10.9mm -25°C CSL
RS Stock No. 919-4696
Mfr. Part No.LF 210-S
BrandLEM
SGD82.77
Each
units
- Closed Loop ±420A ±0.21A ±11.4 → ±15.75 V - - - Panel Mount 100 kHz ±0.2 % - -40°C LF
RS Stock No. 207-2877
Mfr. Part No.HTA 100-S
BrandLEM
SGD101.60
Each
units
- Open Loop ±300A - 15 V - - Hall Effect Panel Mount DC to 50 kHz ±1 % 32mm -25°C HTA
RS Stock No. 337-2724
Mfr. Part No.2814731
SGD753.44
Each
units
- - 0 → 11A 0 → 20mA 20 → 30 V dc - - - Chassis Mount 15 → 400 Hz <0.5 % - -20°C MCR-S-1-5-UI-SW-DCI-NC
RS Stock No. 833-2875
Mfr. Part No.2CCA880100R0001
BrandABB
SGD137.63
Each
units
- - 80A - 690 V ac, 1500 V dc - - CMS Sensor Cable Mount 50/60 Hz ±0.7 % 10mm -25°C CMS
Related Products
AC / DC transformer with integrated signal preparationMeasures ...
Description:
AC / DC transformer with integrated signal preparationMeasures currents with VFD and SCR wavelengthElectrical isolationActual output; voltage or currentNo excess lossesCable entry to 32 mm ØSimple installation.
The PACT RCP Current Transformer Kit for retrofitting ...
Description:
The PACT RCP Current Transformer Kit for retrofitting for alternating currents up to 4000 Aac. Kit consisting of 2 components: 1 A measuring transducer and a Rogowski coilHigh system availability due to easy installation without removing system partsTransform alternating currents ...
Various formats for a wide range of applications. ...
Description:
Various formats for a wide range of applications. IP67 (IP50 E32-L25) All fibres are 2m long black PE. Permissable bend radius 25mm min.Trim to length with the cutting tool supplied for insertion into amplifier clamping aperturesOperating temperature range -40° to ...
Specially adapted to the requirements of industrial applicationsWide ...
Description:
Specially adapted to the requirements of industrial applicationsWide selection helps with adaptation to your applicationPermissible temperature range -40 °C → +70 °C2 metre lengthCan freely be cut to length.