Signal Conditioning

A signal conditioner is a device that converts one type of electronic signal into another type of signal. Its primary use is to convert a signal that may be difficult to read by conventional instrumentation into a more easily read format.
How it works
Signal conditioning can perform a wide range of processes required to make sensor output suitable for processing include amplification, filtering, converting, range matching, isolation. The input from a sensor is connected to the signal conditioner, which is then able to convert the specific input type into a signal that produces the necessary output type for the instrumentation used.
Types of Signal Conditioning
• DIN Rail Mount - a DIN Rail mount signal conditioner mounts on a DIN Rail bracket and are very popular in industrial applications since they provide a rugged mounting format.
• Backplane Mount Conditioners - The backplane style provides the advantage of all output signals being accessible through a single common connector. Backplane signal conditioners are often used with data acquisition systems.
• Digital Sensor Signal Conditioners - The output of a digital signal conditioner is converted to a digital format such as RS232, RS485 or Ethernet. Digital signals provide a high degree of immunity from electrical noise, and can also support extended transmission distances.

...
Read more Read less

Filters

Viewing 1 - 20 of 513 products
Results per page
Description Price Output Type Input Range Output Range Supply Voltage Mounting Type Minimum Operating Temperature Maximum Operating Temperature Hazardous Area Certification Interface Number of Channels Operating Temperature Range Series Standards Met Termination
RS Stock No. 794-8552
BrandRS PRO
SGD176.36
Each
units
- 4 → 20 mA 0 → 10 V 16.8 → 30 V dc, 19.2 → 28.8 V ac DIN Rail -25°C +60°C - - - -25 → +60 °C - CSA Certified, GL, UL Listed Screw
RS Stock No. 218-4447
BrandRS PRO
SGD323.37
Each
units
- 4 → 20 mA - 10 → 30 V dc DIN Rail 0°C +50°C - - - 0 → +50 °C - - Screw
RS Stock No. 466-2292
BrandRS PRO
SGD346.57
Each
units
- 0 → 10 mA, -250 → +250 V dc 0 → 20 mA 115 V ac - 0°C +45°C - - - 0 → +45 °C - - Screw
RS Stock No. 794-8558
BrandRS PRO
SGD181.51
Each
units
- 4 → 20 mA 4 → 20 mA 16.8 → 30 V dc, 19.2 → 28.8 V ac DIN Rail -25°C +60°C - - - -25 → +60 °C - Class I, cULus, Div. 2, Groups A, Groups B, Groups C, Groups D, Groups T4 Screw
RS Stock No. 629-500
BrandRS PRO
SGD352.72
Each
units
- 4 → 20 mA 4 → 20 mA 24 → 230 V ac DIN Rail -20°C +60°C - - - -20 → +60 °C - - Screw
RS Stock No. 466-2400
BrandRS PRO
SGD334.52
Each
units
- 0 → 20 mA, 0 → 250 V ac, -250 → +250 V dc - 230 V ac DIN Rail 0°C +45°C - - - 0 → +45 °C - - Screw
RS Stock No. 466-2264
BrandRS PRO
SGD348.77
Each
units
- 4 → 20 mA 2 x 4 → 20 mA 9 → 30 V dc DIN Rail 0°C +45°C - - - 0 → +45 °C - - Screw
RS Stock No. 629-522
BrandRS PRO
SGD364.34
Each
units
- 0 → 10 V dc 4 → 20 mA 24 → 230 V ac DIN Rail -20°C +60°C - - - -20 → +60 °C - - Screw
RS Stock No. 629-465
BrandRS PRO
SGD325.87
Each
units
- 4 → 20 mA 2 A, 220 V dc, 250 V ac 115 V ac, 230 V ac DIN Rail 0°C +45°C - - - 0 → +45 °C - - Screw
RS Stock No. 794-8520
BrandRS PRO
SGD185.83
Each
units
- 4 → 20 mA 4 → 20 mA - DIN Rail -25°C +60°C - - - -25 → +60 °C - Class I, cULus, Div. 2, Groups A, Groups B, Groups C, Groups D, Groups T4 Screw
RS Stock No. 794-8518
BrandRS PRO
SGD231.41
Each
units
- 0 → 10 V, 0 → 20 mA, 4 → 20 mA 0 → 10 V, 0 → 20 mA, 4 → 20 mA 24 → 240 V ac/dc DIN Rail -25°C +60°C - - - -25 → +60 °C - Class I, cULus, Div. 2, Groups A, Groups B, Groups C, Groups D, Groups T4 Screw
RS Stock No. 218-4453
BrandRS PRO
SGD370.97
Each
units
- 4 → 20 mA - 10 → 30 V dc DIN Rail 0°C +50°C - - - 0 → +50 °C - - Screw
RS Stock No. 218-4469
BrandRS PRO
SGD350.92
Each
units
- 0 → 20 mA, -250 → +250 V dc 0 → 10 mA, 0 → 10 V dc 10 → 30 V dc DIN Rail 0°C +50°C - - - 0 → +50 °C - - Screw
RS Stock No. 466-2258
BrandRS PRO
SGD237.61
Each
units
- 4 → 20 mA 0 → 10 V 24 V dc DIN Rail 0°C +45°C - - - 0 → +45 °C - - Screw
RS Stock No. 794-8580
BrandRS PRO
SGD281.33
Each
units
- 4 → 20 mA 4 → 20 mA - DIN Rail -25°C +60°C - - - -25 → +60 °C - Class I, cULus, Div. 2, Groups A, Groups B, Groups C, Groups D, Groups T4 Screw
RS Stock No. 794-8568
BrandRS PRO
SGD161.65
Each
units
- 0 → 20 mA, 4 → 20 mA 0 → 20 mA, 4 → 20 mA - DIN Rail -25°C +60°C - - - -25 → +60 °C - Class I, cULus, Div. 2, Groups A, Groups B, Groups C, Groups D, Groups T4 Screw
RS Stock No. 466-2236
BrandRS PRO
SGD237.61
Each
units
- 0 → 10 V 0 → 10 V 24 V dc DIN Rail 0°C +45°C - - - 0 → +45 °C - - Screw
RS Stock No. 466-2286
BrandRS PRO
SGD253.77
Each
units
- 4 - 20 mA - 115 V ac DIN Rail 0°C +45°C - - - 0 → +45 °C - - Screw
RS Stock No. 466-2270
BrandRS PRO
SGD253.77
Each
units
- 0 → 10 mA, -250 → +250 V dc 2 A, 220 V dc, 250 V ac 230 V ac - 0°C +45°C - - - 0 → +45 °C - - Screw
RS Stock No. 794-8574
BrandRS PRO
SGD325.43
Each
units
- 0 → 10 V, 0 → 20 mA, 4 → 20 mA 0 → 10 V, 0 → 20 mA, 4 → 20 mA 16.8 → 30 V DIN Rail -40°C +70°C - - - -40 → +70 °C - cULus Screw
Related Products
Wago 857 series JUMPFLEX configurable isolation amplifiers convert, ...
Description:
Wago 857 series JUMPFLEX configurable isolation amplifiers convert, amplify, filter and electrically isolate standard analogue signals. Clipping capability provides analogue signal limitation to output end values Calibrated scale switching PC configuration interface Safe 3 way isolation with 4 kV test ...
Wago 857 series JUMPFLEX threshold value switch for ...
Description:
Wago 857 series JUMPFLEX threshold value switch for monitoring analogue standard signals and reporting signals exceeding a preset threshold. PC configuration interface Digital switching output Changeover contact relay output Calibrated scale switching Threshold value configuration via DIP switches and teach-in ...
Wago 857 series JUMPFLEX configurable isolation amplifiers convert, ...
Description:
Wago 857 series JUMPFLEX configurable isolation amplifiers convert, amplify, filter and electrically isolate standard analogue signals. Clipping capability provides analogue signal limitation to output end values Calibrated scale switching PC configuration interface Safe 3 way isolation with 4 kV test ...
Wago 857 series JUMPFLEX configurable isolation amplifiers convert, ...
Description:
Wago 857 series JUMPFLEX configurable isolation amplifiers convert, amplify, filter and electrically isolate standard analogue signals. Clipping capability provides analogue signal limitation to output end values Calibrated scale switching PC configuration interface Safe 3 way isolation with 4 kV test ...